| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 2.0 | - | 5.5 | V |
| Input Voltage | VI | Relative to GND | -0.5 | - | VCC + 0.5 | V |
| Output Voltage (High) | VOH | IOL = -400 渭A | - | - | VCC - 0.1 | V |
| Output Voltage (Low) | VOL | IOH = 16 mA | 0.2 | - | - | V |
| Input Leakage Current | IIL | VI = 0 V, VCC = 5 V | -1 | - | 1 | 渭A |
| Output Leakage Current | IOL | VO = 0 V, VCC = 5 V | -1 | - | 1 | 渭A |
| Propagation Delay Time | tpd | VCC = 5 V, TA = 25掳C | 4 | - | 8 | ns |
| Power Dissipation | PD | Continuous | - | - | 340 | mW |
| Operating Temperature | TA | Operating | -40 | - | 85 | 掳C |
| Storage Temperature | TSTG | Storage | -65 | - | 150 | 掳C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.0 V to 5.5 V.
- Connect the ground (GND) pin to a stable reference point.
Input Handling:
- The input voltage (VI) should not exceed VCC + 0.5 V or go below -0.5 V to avoid damage.
- Ensure input signals are clean and stable to prevent unintended switching.
Output Handling:
- The output high voltage (VOH) will be close to VCC when the output is high, with a typical drop of 0.1 V.
- The output low voltage (VOL) will be close to 0 V when the output is low, with a typical rise of 0.2 V.
- Ensure the load connected to the output does not exceed the maximum current ratings.
Timing Considerations:
- The propagation delay time (tpd) is the time it takes for a change at the input to appear at the output. It ranges from 4 ns to 8 ns at VCC = 5 V and 25掳C.
Thermal Management:
- The device can dissipate up to 340 mW continuously. Ensure proper heat sinking if operating near this limit.
- The operating temperature range is -40掳C to 85掳C. Avoid exceeding these limits to prevent thermal damage.
Storage:
- Store the device in a dry, cool place within the storage temperature range of -65掳C to 150掳C to maintain reliability.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
Mounting:
- Ensure proper mounting to avoid mechanical stress on the pins and package.
- Use appropriate soldering techniques to ensure reliable connections.