TC74VHC244FK

TC74VHC244FK


Specifications
SKU
12600012
Details

BUY TC74VHC244FK https://www.utsource.net/itm/p/12600012.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 2.0 - 5.5 V
Input Voltage VI Relative to GND -0.5 - VCC + 0.5 V
Output Voltage (High) VOH IOL = -400 渭A - - VCC - 0.1 V
Output Voltage (Low) VOL IOH = 16 mA 0.2 - - V
Input Leakage Current IIL VI = 0 V, VCC = 5 V -1 - 1 渭A
Output Leakage Current IOL VO = 0 V, VCC = 5 V -1 - 1 渭A
Propagation Delay Time tpd VCC = 5 V, TA = 25掳C 4 - 8 ns
Power Dissipation PD Continuous - - 340 mW
Operating Temperature TA Operating -40 - 85 掳C
Storage Temperature TSTG Storage -65 - 150 掳C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.0 V to 5.5 V.
    • Connect the ground (GND) pin to a stable reference point.
  2. Input Handling:

    • The input voltage (VI) should not exceed VCC + 0.5 V or go below -0.5 V to avoid damage.
    • Ensure input signals are clean and stable to prevent unintended switching.
  3. Output Handling:

    • The output high voltage (VOH) will be close to VCC when the output is high, with a typical drop of 0.1 V.
    • The output low voltage (VOL) will be close to 0 V when the output is low, with a typical rise of 0.2 V.
    • Ensure the load connected to the output does not exceed the maximum current ratings.
  4. Timing Considerations:

    • The propagation delay time (tpd) is the time it takes for a change at the input to appear at the output. It ranges from 4 ns to 8 ns at VCC = 5 V and 25掳C.
  5. Thermal Management:

    • The device can dissipate up to 340 mW continuously. Ensure proper heat sinking if operating near this limit.
    • The operating temperature range is -40掳C to 85掳C. Avoid exceeding these limits to prevent thermal damage.
  6. Storage:

    • Store the device in a dry, cool place within the storage temperature range of -65掳C to 150掳C to maintain reliability.
  7. Handling Precautions:

    • Handle the device with care to avoid static discharge, which can damage the internal circuits.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
  8. Mounting:

    • Ensure proper mounting to avoid mechanical stress on the pins and package.
    • Use appropriate soldering techniques to ensure reliable connections.
(For reference only)