TM1652

TM1652


Specifications
SKU
12600298
Details

BUY TM1652 https://www.utsource.net/itm/p/12600298.html

Parameter Description Value
Operating Voltage (Vcc) Supply voltage range for operation 2.4V to 5.5V
Operating Current Typical current consumption during operation 10mA (max)
Standby Current Current consumption in standby mode 10渭A (max)
Operating Temperature Temperature range for reliable operation -40掳C to +85掳C
Storage Temperature Temperature range for storage -40掳C to +85掳C
Display Digits Number of digits supported 8 digits (7-segment)
Digit Height Height of each digit 14mm
Common Cathode/Anode Type of display connection Common Cathode
Communication Interface Type of communication protocol 3-wire serial interface (CLK, DIO, VCC)
Data Rate Maximum data transmission rate 400kHz
Refresh Rate Typical refresh rate for stable display 100Hz (min)
Display Brightness Adjustable brightness levels 4 levels (0-3)
Command Set Number of commands available for control 16 commands

Instructions for Using TM1652

  1. Power Supply Connection:

    • Connect the VCC pin to the positive supply voltage (2.4V to 5.5V).
    • Connect the GND pin to the ground.
  2. Communication Interface:

    • Connect the CLK pin to the clock signal from the microcontroller.
    • Connect the DIO pin to the data input/output signal from the microcontroller.
    • Ensure that the communication lines are properly pulled up with resistors if necessary.
  3. Initialization:

    • Send the initialization command (0x40) to reset the display and set it to normal operation mode.
    • Set the address pointer to the first digit by sending the address command (0xC0).
  4. Display Data:

    • Send the data to be displayed on the segments. Each digit is controlled by sending a 7-bit data byte.
    • For example, to display "1" on the first digit, send 0x06 (binary 00000110).
  5. Brightness Control:

    • Adjust the brightness using the brightness control command (0x80 + brightness level). The brightness level can be 0, 1, 2, or 3.
    • Example: To set the brightness to level 2, send 0x82.
  6. Command Set:

    • Use the command set to control various functions such as display test, shutdown, and address setting.
    • Refer to the datasheet for a complete list of commands and their usage.
  7. Error Handling:

    • Monitor the status of the display and communication lines to ensure proper operation.
    • Implement error handling routines to manage any communication failures or display issues.
  8. Power Management:

    • Use the shutdown command (0x40) to put the display into low-power mode when not in use.
    • Reactivate the display by sending the initialization command again.
  9. Example Code:

    • Initialize the display:
      void TM1652_Init() {
          TM1652_SendCommand(0x40); // Initialization command
          TM1652_SendCommand(0x82); // Set brightness to level 2
          TM1652_SendCommand(0xC0); // Set address pointer to the first digit
      }
      
    • Display a number:
      void TM1652_DisplayNumber(uint8_t digit, uint8_t value) {
          TM1652_SendCommand(0xC0 + digit); // Set address pointer to the desired digit
          TM1652_SendData(value); // Send the data to be displayed
      }
      
  10. Note:

    • Always refer to the datasheet for detailed information and specific implementation details.