BUY 855AP-1A-C 24VDC https://www.utsource.net/itm/p/12600708.html
Below is the parameter table and instructions for the 855AP-1A-C 24VDC relay module.
Parameter Table
| Parameter | Value |
|---|---|
| Model Number | 855AP-1A-C 24VDC |
| Supply Voltage | 24V DC |
| Current Consumption | ≤ 20mA (Typical) |
| Control Input | 3-30V DC |
| Relay Type | SPDT (Single Pole Double Throw) |
| Contact Rating | 10A @ 250V AC / 10A @ 30V DC |
| Switching Capacity | 600W @ 250V AC / 300W @ 30V DC |
| Insulation Resistance | > 100MΩ at 500V DC |
| Dielectric Strength | 2500V AC for 1 minute |
| Operating Temperature | -25°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5% to 95% RH (Non-condensing) |
| Dimensions | 35mm x 22.5mm x 15mm |
| Weight | 20g |
Instructions
Installation:
- Ensure the relay module is installed in a well-ventilated area to prevent overheating.
- Mount the relay on a DIN rail or use the provided mounting holes for secure installation.
Power Supply Connection:
- Connect the 24V DC power supply to the "V+" and "GND" terminals of the relay module.
- "V+" is the positive terminal and "GND" is the ground terminal.
Control Input Connection:
- Connect the control signal to the "IN" terminal.
- The control input can accept a range of 3-30V DC.
- When the control voltage is applied, the relay will energize and switch the contacts.
Load Connection:
- Connect the load to the "COM", "NO" (Normally Open), and "NC" (Normally Closed) terminals.
- "COM" is the common terminal.
- "NO" is the normally open contact, which closes when the relay is energized.
- "NC" is the normally closed contact, which opens when the relay is energized.
Operation:
- When the control input is active (voltage applied), the relay will switch the contacts from NC to NO.
- When the control input is inactive (no voltage applied), the relay will switch the contacts back to NC.
Safety Precautions:
- Do not exceed the maximum ratings for voltage and current.
- Ensure all connections are secure to prevent arcing and damage.
- Use appropriate fuses or circuit breakers to protect the relay and connected devices.
- Avoid operating the relay in environments with high humidity or corrosive gases.
Maintenance:
- Regularly inspect the relay for signs of wear or damage.
- Clean the relay with a dry cloth to remove dust and debris.
- Replace the relay if it shows signs of malfunction or damage.
By following these instructions, you can ensure the safe and reliable operation of the 855AP-1A-C 24VDC relay module.