Details
BUY LM2903QD https://www.utsource.net/itm/p/12601136.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage Range | Vcc | 2 | 36 | V | ||
Output Low Voltage | VOL | IOL = 16mA, VCC = 5V | 0.4 | V | ||
Output High Voltage | VOH | IOH = -4.5mA, VCC = 5V | 4.4 | V | ||
Input Offset Voltage | VIO | TA = 25°C | 2 | mV | ||
Input Bias Current | IB | TA = 25°C | 25 | nA | ||
Supply Current | ICC | No load | 350 | μA | ||
Common Mode Input Range | VICR | 0 | Vcc-1.5 | V | ||
Differential Input Voltage | VID | Continuous | ±30 | V | ||
Operating Temperature | Topr | -40 | 125 | °C |
Instructions for LM2903QD
Power Supply Connection:
- Connect the supply voltage (Vcc) between the V+ and GND pins. Ensure that the supply voltage is within the specified range of 2V to 36V.
Input Connections:
- Connect the non-inverting (+) and inverting (-) inputs as required by your circuit design. Be cautious not to exceed the differential input voltage limits of ±30V to prevent damage.
Output Configuration:
- The output is open-collector and requires a pull-up resistor connected to the desired logic level. Ensure the output current ratings are not exceeded.
Thermal Considerations:
- Operate the device within the temperature range of -40°C to 125°C. For applications requiring high reliability, consider thermal management techniques if operating near the upper limit.
Handling Precautions:
- This device is sensitive to electrostatic discharge (ESD). Use proper ESD protection practices during handling and installation.
Stability and Compensation:
- For stability, ensure the input signals do not cause excessive slew rates or oscillations. External compensation components may be necessary depending on the application.
Testing and Troubleshooting:
- Verify all connections and supply voltages before powering up. Monitor the output behavior and adjust component values as needed for optimal performance.
View more about LM2903QD on main site