Details
BUY ULN2803G https://www.utsource.net/itm/p/12602719.html
| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | - | 55 | V | Operating range for all functions |
| Output Current (per channel) | IO | - | 500 | - | mA | Maximum continuous current per Darlington pair |
| Peak Output Current (per channel) | IOPK | - | 600 | - | mA | Short duration, non-repetitive |
| Input Current | II | - | 1.6 | - | mA | At VI = 5V |
| Input Voltage (High) | VIH | 2.0 | - | 55 | V | Minimum input voltage to ensure high logic level |
| Input Voltage (Low) | VIL | 0 | - | 0.8 | V | Maximum input voltage to ensure low logic level |
| Output Voltage (Saturation) | VCE(sat) | - | 1.0 | - | V | At IO = 500mA |
| Storage Temperature | TSTG | -65 | - | 150 | °C | Temperature range for storage |
| Operating Temperature | TA | 0 | - | 70 | °C | Ambient temperature range for operation |
| Thermal Resistance (θJA) | - | - | 75 | - | °C/W | Junction-to-ambient thermal resistance |
| Power Dissipation | PD | - | 650 | - | mW | Maximum power dissipation per Darlington pair at TA = 25°C |
Instructions for Use
Power Supply:
- Ensure the supply voltage (VCC) is within the specified range (4.5V to 55V).
- Connect the VCC pin to the positive supply and the GND pin to the ground.
Input Signals:
- Apply logic high (VIH ≥ 2.0V) or logic low (VIL ≤ 0.8V) signals to the input pins.
- The input current (II) should not exceed 1.6mA at VI = 5V.
Output Loads:
- Connect the load between the output pins and the ground.
- Ensure the continuous output current (IO) does not exceed 500mA per channel.
- For short-duration, non-repetitive loads, the peak output current (IOPK) can be up to 600mA.
Thermal Management:
- Monitor the ambient temperature (TA) to ensure it stays within the operating range (0°C to 70°C).
- If the device is operating near its maximum power dissipation (PD = 650mW), consider using a heatsink or improving airflow.
Storage:
- Store the device in an environment with temperatures between -65°C and 150°C.
Handling:
- Handle the device with care to avoid static damage.
- Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
By adhering to these parameters and instructions, you can ensure reliable and efficient operation of the ULN2803G.
(For reference only)View more about ULN2803G on main site