| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | 3 | 15 | V | Operating supply voltage range | |
| Supply Current (Quiescent) | IQ | 1 | 10 | 渭A | Quiescent current at VDD = 15V | |
| Input Low Voltage | VIL | 0 | 1.5 | V | Maximum input low voltage | |
| Input High Voltage | VIH | 3.5 | 15 | V | Minimum input high voltage | |
| Output Low Voltage | VOL | 0 | 0.1 | 0.5 | V | Maximum output low voltage |
| Output High Voltage | VOH | 2.4 | VDD - 0.6 | V | Minimum output high voltage | |
| Output Current (Sink) | IOL | -10 | -100 | mA | Maximum output sink current | |
| Output Current (Source) | IOH | 10 | 100 | 渭A | Maximum output source current | |
| Propagation Delay Time | tpd | 10 | 70 | ns | Typical propagation delay time | |
| Power Dissipation | PD | 100 | mW | Maximum power dissipation per channel |
Instructions for Using HEF4053BP
Supply Voltage:
- Ensure the supply voltage (VDD) is within the specified range of 3V to 15V.
- Connect the positive terminal of the power supply to VDD and the negative terminal to GND.
Input Signals:
- Apply logic levels to the input pins (IN1, IN2, IN3) such that they are either below VIL (0V to 1.5V) for a low signal or above VIH (3.5V to 15V) for a high signal.
- Ensure the input signals do not exceed the supply voltage range to avoid damage.
Output Signals:
- The output pins (OUT1, OUT2, OUT3) will provide logic levels based on the state of the corresponding input and control signals.
- The output low voltage (VOL) will be between 0V and 0.5V, and the output high voltage (VOH) will be between 2.4V and VDD - 0.6V.
- The output can sink up to 100mA and source up to 100渭A.
Control Signals:
- Use the control pins (S0, S1, S2) to select which input is connected to the output. Each combination of S0, S1, and S2 selects one of the eight possible input-output pairs.
- Ensure the control signals are within the same logic level ranges as the input signals.
Power Dissipation:
- Monitor the power dissipation to ensure it does not exceed 100mW per channel to prevent overheating and potential damage.
Handling and Storage:
- Handle the HEF4053BP with care to avoid static discharge, which can damage the component.
- Store the device in a dry, cool place away from direct sunlight and sources of heat.