6N137

6N137


Specifications
SKU
12602899
Details

BUY 6N137 https://www.utsource.net/itm/p/12602899.html

Parameter Symbol Min Typical Max Unit Conditions
Forward Current Transfer Ratio (CTR) CTR - 50% - - VCC = 5V, IF = 5mA, VO = 5V, RL = 1k惟
Input Current IF 1.0 - - mA VCC = 5V, VI = 1.2V
Output Voltage (High) VOH - 4.5 5.0 V VCC = 5V, IL = -4.0mA
Output Voltage (Low) VOL 0.4 - 0.8 V VCC = 5V, IL = 16.0mA
Propagation Delay Time (Low to High) tPLH - 45 100 ns VCC = 5V, VI = 1.2V, VO = 2.5V, RL = 1k惟
Propagation Delay Time (High to Low) tPHL - 45 100 ns VCC = 5V, VI = 1.2V, VO = 2.5V, RL = 1k惟
Rise Time tr - 15 35 ns VCC = 5V, VI = 1.2V, VO = 2.5V, RL = 1k惟
Fall Time tf - 15 35 ns VCC = 5V, VI = 1.2V, VO = 2.5V, RL = 1k惟
Storage Temperature Range TSTG -40 - 125 掳C -
Operating Temperature Range TA 0 - 70 掳C -

Instructions for Using 6N137 Optocoupler:

  1. Power Supply (VCC):

    • Ensure the supply voltage is within the specified range (4.75V to 5.25V) for optimal performance.
    • Connect VCC to the positive power supply and GND to the ground.
  2. Input Side:

    • Apply the input signal to the anode (pin 1) and cathode (pin 2) of the internal LED.
    • The forward current (IF) should be within the recommended range (1.0mA to 20mA).
  3. Output Side:

    • Connect the load resistor (RL) between the output (pin 4) and ground.
    • The output voltage (VO) will be high (close to VCC) when the LED is off and low (close to 0V) when the LED is on.
  4. Propagation Delay:

    • Be aware of the propagation delay times (tPLH and tPHL) when designing timing-critical circuits.
  5. Temperature Considerations:

    • Operate the device within the specified temperature ranges to avoid damage and ensure reliable operation.
  6. Handling Precautions:

    • Handle the device with care to avoid static discharge, which can damage the sensitive components.
    • Store the device in a dry environment to prevent moisture-related issues.
  7. Mounting:

    • Ensure proper soldering and mounting techniques to maintain electrical connections and mechanical integrity.

By following these guidelines, you can effectively use the 6N137 optocoupler in your applications.

(For reference only)