| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Operating Voltage | Vcc | 4.5 | - | 5.5 | V | |
| Standby Current | Icc | - | 10 | - | μA | At Vcc = 5V, Ta = 25°C |
| Output Voltage | Vo | - | 5.0 | - | V | Fixed output voltage |
| Load Regulation | ΔVo/ΔI | - | 0.5 | - | % | From 0 to 100mA |
| Line Regulation | ΔVo/ΔV | - | 0.1 | - | %/V | From 4.5V to 5.5V |
| Dropout Voltage | Vdo | - | 0.3 | - | V | At Io = 100mA, Ta = 25°C |
| Thermal Shutdown | Tsd | - | 150 | - | °C | |
| Short-Circuit Protection | Isc | - | 1.5 | - | A | Continuous at Ta = 25°C |
| Storage Temperature | Tstg | -40 | - | 85 | °C | |
| Operating Temperature | Topr | -40 | - | 85 | °C |
Instructions:
Power Supply:
- Ensure the input voltage (Vcc) is within the range of 4.5V to 5.5V.
- Use a decoupling capacitor (0.1μF) close to the Vcc pin to stabilize the power supply.
Output Configuration:
- The output voltage (Vo) is fixed at 5.0V. No external resistors are required for voltage setting.
- Connect the load directly to the output pin (Vo).
Thermal Management:
- The device has built-in thermal shutdown protection, which activates at approximately 150°C.
- Ensure adequate heat dissipation if operating under high load conditions or in high ambient temperatures.
Protection Features:
- The device includes short-circuit protection, limiting the output current to approximately 1.5A.
- If a short circuit occurs, the device will automatically limit the current to prevent damage.
Environmental Conditions:
- The device can operate over a temperature range from -40°C to 85°C.
- Store the device in an environment with a temperature range from -40°C to 85°C.
Handling and Installation:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Follow standard surface mount technology (SMT) procedures for installation.
Testing:
- Before final assembly, test the device to ensure it meets the specified electrical parameters.
- Verify the output voltage and current regulation under various load conditions.
View more about MK68901Q-05 on main site