JS1A-48V

JS1A-48V


Specifications
SKU
12602952
Details

BUY JS1A-48V https://www.utsource.net/itm/p/12602952.html

Parameter Value Description
Part Number JS1A-48V -
Type Reed Relay A reed relay with a 48V coil voltage.
Coil Voltage (Vdc) 48 Nominal operating voltage of the relay coil.
Coil Current (mA) 7.3 Current required to energize the relay coil.
Power Consumption (W) 0.3504 Power consumed by the relay when energized.
Contact Form SPST (Single Pole Single Throw) Relay has one set of contacts that can be either open or closed.
Contact Rating 2A at 250VAC / 30VDC Maximum current and voltage the contacts can handle under load.
Insulation Resistance (M惟) 1000 @ 500VDC Minimum resistance between the coil and contacts when de-energized.
Dielectric Strength (Vrms) 1500 @ 50/60Hz Maximum voltage the relay can withstand without breakdown.
Operating Temperature (掳C) -40 to +85 Temperature range within which the relay can operate reliably.
Storage Temperature (掳C) -40 to +125 Temperature range for storing the relay without damage.
Humidity 95% RH (non-condensing) Maximum relative humidity the relay can withstand without condensation.
Mechanical Life (Cycles) 10,000,000 Number of expected operations before mechanical failure.
Electrical Life (Cycles) 100,000 (resistive load) Number of expected operations before electrical failure under resistive load.
Dimensions (mm) 12.7 x 7.9 x 12.7 Physical size of the relay.
Weight (g) 2.5 Weight of the relay.

Instructions:

  1. Installation:

    • Ensure the relay is mounted on a flat, stable surface.
    • Use appropriate fasteners to secure the relay in place.
    • Avoid exposing the relay to excessive mechanical stress or vibration.
  2. Wiring:

    • Connect the coil terminals to the control circuit using wires rated for the coil current.
    • Connect the contact terminals to the load circuit according to the application requirements.
    • Ensure all connections are secure and free from short circuits.
  3. Operation:

    • Apply the nominal coil voltage to energize the relay.
    • The contacts will close (or open, depending on the configuration) when the coil is energized.
    • When the coil voltage is removed, the contacts will return to their default state.
  4. Maintenance:

    • Regularly inspect the relay for signs of wear or damage.
    • Clean the relay contacts if necessary using a soft, dry cloth.
    • Do not use abrasive materials or solvents that could damage the relay.
  5. Safety:

    • Always disconnect power before performing any maintenance or wiring changes.
    • Follow all local electrical codes and safety guidelines.
    • Use appropriate personal protective equipment (PPE) when handling electrical components.
(For reference only)

View more about JS1A-48V on main site