Details
BUY PSS30S92F6-AG https://www.utsource.net/itm/p/12603381.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 5.5 | V | |
| Output Voltage | VOUT | 3.3 | - | 3.3 | V | Fixed |
| Output Current | IOUT | - | 2 | 3 | A | |
| Efficiency | η | - | 92 | - | % | At nominal conditions |
| Quiescent Current | IQ | - | 10 | 20 | μA | Shutdown mode |
| Dropout Voltage | VDROPOUT | - | 120 | 180 | mV | At IOUT = 3A |
| Load Regulation | ΔVOUT/ΔIOUT | - | 0.5 | 1.5 | mV/A | From 0 to 3A |
| Line Regulation | ΔVOUT/ΔVIN | - | 0.5 | 1.5 | mV/V | From 4.5V to 5.5V |
| Operating Temperature | TOPR | -40 | - | 85 | °C | |
| Storage Temperature | TSTG | -65 | - | 150 | °C |
Instructions for Use
Input Connection:
- Connect the input voltage (VIN) to the positive terminal of the PSS30S92F6-AG.
- Ensure the input voltage is within the specified range of 4.5V to 5.5V.
Output Connection:
- Connect the output voltage (VOUT) to the load.
- The output voltage is fixed at 3.3V and can supply up to 3A of current.
Ground Connection:
- Connect the ground (GND) of the input and output to a common ground point.
Thermal Management:
- Ensure adequate heat dissipation, especially when operating at high output currents.
- Use a heatsink if necessary to maintain the operating temperature within the specified range (-40°C to 85°C).
Efficiency:
- The device has a typical efficiency of 92% under nominal conditions. Monitor power consumption and heat generation during operation.
Quiescent Current:
- In shutdown mode, the quiescent current is typically 10μA and can go up to 20μA. Use this information for low-power applications.
Dropout Voltage:
- The dropout voltage is typically 120mV and can go up to 180mV at maximum output current. Ensure the input voltage is sufficiently higher than the output voltage to maintain regulation.
Regulation:
- The load regulation is typically 0.5mV/A and can go up to 1.5mV/A.
- The line regulation is typically 0.5mV/V and can go up to 1.5mV/V.
Storage:
- Store the device in a dry environment with temperatures between -65°C and 150°C.
Handling:
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
- Follow standard handling procedures for sensitive electronic components.
For detailed application notes and further technical information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about PSS30S92F6-AG on main site