SPA08N80C3

SPA08N80C3


Specifications
SKU
12603803
Details

BUY SPA08N80C3 https://www.utsource.net/itm/p/12603803.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source Voltage VDS - 800 - V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current ID - 8 - A @ TC = 25掳C
Pulse Drain Current ID pul - 16 - A tp = 10 渭s, IG = 4 A
Power Dissipation PTOT - - 115 W @ TC = 25掳C
Junction Temperature TJ -55 - 175 掳C
Storage Temperature TSTG -55 - 150 掳C
Thermal Resistance, Junction to Case RthJC - 0.85 - K/W
Total Gate Charge QG - 90 - nC
Input Capacitance Ciss - 1450 - pF @ VDS = 400 V, f = 1 MHz
Output Capacitance Coss - 350 - pF @ VDS = 400 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 100 - pF @ VDS = 400 V, f = 1 MHz
On-State Resistance RDS(on) - 0.85 - @ VGS = 10 V, ID = 8 A, TJ = 25掳C
Turn-On Delay Time td(on) - 40 - ns @ VDS = 400 V, ID = 8 A, RG = 10 惟
Rise Time tr - 45 - ns @ VDS = 400 V, ID = 8 A, RG = 10 惟
Turn-Off Delay Time td(off) - 40 - ns @ VDS = 400 V, ID = 8 A, RG = 10 惟
Fall Time tf - 45 - ns @ VDS = 400 V, ID = 8 A, RG = 10 惟

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to manage the power dissipation.
    • Handle with care to avoid damage to the pins and the die.
  2. Biasing:

    • Apply the gate-source voltage (VGS) within the specified range to ensure reliable operation.
    • Use appropriate gate resistors to control the switching speed and minimize switching losses.
  3. Thermal Management:

    • Monitor the junction temperature (TJ) to prevent overheating.
    • Use thermal paste or thermal interface materials to enhance heat transfer from the device to the heatsink.
  4. Operating Conditions:

    • Operate within the maximum ratings for drain-source voltage (VDS), continuous drain current (ID), and power dissipation (PTOT).
    • Avoid exceeding the storage temperature limits (TSTG).
  5. Testing:

    • When testing the device, use the recommended test conditions to ensure accurate measurements.
    • Verify the on-state resistance (RDS(on)) and other key parameters to confirm the device is functioning correctly.
  6. Storage:

    • Store the device in a dry, cool environment to prevent moisture damage.
    • Follow ESD (Electrostatic Discharge) precautions to avoid damaging the device.
  7. Application:

    • The SPA08N80C3 is suitable for high-voltage, high-frequency applications such as switch-mode power supplies, motor control, and industrial electronics.
(For reference only)