Details
BUY TLP759F https://www.utsource.net/itm/p/12603829.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | IF = 20 mA | 1.1 | 1.3 | 1.5 | V |
| Reverse Breakdown Voltage | VR | IR = 1 mA | 5 | - | 7 | V |
| Output Current | IO | VOUT = 4.5 V | 100 | 150 | 200 | mA |
| Propagation Delay Time | tPLH, tPHL | IF = 20 mA, IO = 5 mA | 20 | 30 | 40 | ns |
| Rise Time | tr | IF = 20 mA, IO = 5 mA | 10 | 15 | 20 | ns |
| Fall Time | tf | IF = 20 mA, IO = 5 mA | 10 | 15 | 20 | ns |
| Isolation Voltage | VIORM | Test Condition A | 2.5 | - | 5.0 | kV |
Instructions for Use:
Mounting and Handling:
- Handle the TLP759F with care to avoid mechanical damage.
- Ensure proper mounting on a suitable heat sink if required.
Electrical Connections:
- Connect the device according to the pin configuration diagram provided in the datasheet.
- Ensure correct polarity when connecting the input and output terminals.
Operating Conditions:
- Operate within the specified temperature range (-40掳C to +85掳C).
- Do not exceed the maximum ratings listed in the table.
Power Supply:
- Ensure the power supply voltage is within the rated limits to prevent damage to the device.
Testing:
- For accurate testing, use the conditions specified in the parameter table.
- Use appropriate test equipment to avoid introducing errors.
Storage:
- Store in a dry, cool place away from direct sunlight and corrosive materials.
Safety Precautions:
- Follow all safety guidelines when handling high voltages.
- Use protective gear as necessary during installation and testing.
View more about TLP759F on main site