TCA0372DP2

TCA0372DP2


Specifications
SKU
12603847
Details

BUY TCA0372DP2 https://www.utsource.net/itm/p/12603847.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 1.8 - 5.5 V Operating supply voltage range
Output Current per Channel IO - 50 - mA Maximum output current per channel
Total Output Current IOT - 200 - mA Maximum total output current
High-Level Input Voltage VIH 0.7 - VDD V Minimum input voltage for logic high
Low-Level Input Voltage VIL 0 - 0.3 V Maximum input voltage for logic low
High-Level Output Voltage VOH - VDD-0.4 VDD-0.1 V Minimum output voltage for logic high
Low-Level Output Voltage VOL 0 0.1 0.4 V Maximum output voltage for logic low
Propagation Delay Time tpd - 20 - ns Typical propagation delay time
Power Dissipation PD - - 600 mW Maximum power dissipation
Operating Temperature TOPR -40 - 85 掳C Operating temperature range
Storage Temperature TSTG -65 - 150 掳C Storage temperature range

Instructions:

  1. Power Supply: Ensure the supply voltage (VDD) is within the range of 1.8V to 5.5V.
  2. Output Current: Do not exceed 50mA per channel or 200mA in total to avoid damage.
  3. Input Levels: Use input voltages (VIH and VIL) that comply with the specified levels to ensure proper logic operation.
  4. Output Levels: Verify that the output voltages (VOH and VOL) meet the required levels for the connected circuits.
  5. Propagation Delay: Account for the typical propagation delay of 20ns in timing calculations.
  6. Thermal Management: Keep the operating temperature between -40掳C and 85掳C. Ensure adequate heat dissipation if operating near the maximum power dissipation of 600mW.
  7. Storage Conditions: Store the device in a temperature range of -65掳C to 150掳C to prevent damage.
  8. Handling: Follow standard ESD (Electrostatic Discharge) precautions when handling the device to prevent damage.
(For reference only)