AD587KR

AD587KR


Specifications
SKU
12603894
Details

BUY AD587KR https://www.utsource.net/itm/p/12603894.html

Parameter Symbol Conditions Min Typ Max Unit
Output Voltage Vout Iout = 0 mA 10.00 10.00 10.00 V
Line Regulation ΔVout Vin = 2.4 to 36 V, Iout = 0 mA - 0.001 - %
Load Regulation ΔVout Iout = 0 to 10 mA - 0.001 - %
Temperature Coefficient TCVout -40°C to +85°C - 5 - ppm/°C
Output Current Iout Continuous 0 10 - mA
Dropout Voltage Vdo Iout = 10 mA 0.2 0.5 1.0 V
Power Dissipation Pdiss Ta = 25°C - 1.1 - W
Operating Temperature Ta - -40 - 85 °C
Storage Temperature Tstg - -65 - 150 °C

Instructions for Use:

  1. Power Supply:

    • The AD587KR can operate with an input voltage range from 2.4 V to 36 V.
    • Ensure the input voltage is stable and within the specified range to avoid damage or performance degradation.
  2. Output Voltage:

    • The output voltage is fixed at 10.00 V under no-load conditions.
    • The load regulation is very low (0.001%), ensuring minimal voltage drop even when the output current changes.
  3. Temperature Considerations:

    • The temperature coefficient is 5 ppm/°C, which means the output voltage will change by 50 μV for every 10°C change in temperature.
    • The operating temperature range is from -40°C to +85°C, and the storage temperature range is from -65°C to +150°C.
  4. Output Current:

    • The maximum continuous output current is 10 mA.
    • Ensure that the load does not exceed this limit to prevent overheating or damage.
  5. Dropout Voltage:

    • The dropout voltage, the difference between the input and output voltages, is typically 0.5 V at 10 mA.
    • Ensure that the input voltage is at least 0.5 V higher than the desired output voltage to maintain regulation.
  6. Power Dissipation:

    • The maximum power dissipation at 25°C ambient temperature is 1.1 W.
    • Proper heat sinking may be required if operating at high temperatures or high power levels.
  7. Mounting and Handling:

    • Handle the device with care to avoid mechanical stress or damage.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
  8. Testing and Verification:

    • After installation, verify the output voltage and ensure it meets the required specifications.
    • Check for any unusual heating or performance issues during operation.

By following these instructions, you can ensure optimal performance and longevity of the AD587KR reference voltage source.

(For reference only)

View more about AD587KR on main site