| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 8 | - | 30 | V | Operating voltage range |
| Logic Supply Voltage | VLOGIC | 2.5 | - | 5.5 | V | Logic supply voltage range |
| Peak Output Current | IOUT | - | 1.4 | - | A | Peak output current per channel |
| Thermal Shutdown | TSD | - | 160 | - | 掳C | Thermal shutdown temperature |
| Under-Voltage Lockout | UVLO | 6.5 | - | 7.5 | V | Under-voltage lockout threshold (rising) |
| Sleep Mode Current | ISLP | - | 10 | - | 渭A | Current consumption in sleep mode |
| Active Mode Current | IACT | - | 50 | - | mA | Typical current consumption in active mode |
Instructions for Using the A3988SJPT
Power Supply Connection:
- Connect the VCC pin to a power supply within the range of 8V to 30V.
- Connect the VLOGIC pin to a logic supply between 2.5V and 5.5V.
Motor Connections:
- Connect motor coils to the OUT1, OUT2, OUT3, and OUT4 pins as per the motor configuration.
Control Signals:
- Use STEP and DIR pins to control stepping and direction of the motor.
- Set the SLEEP pin high to activate the device or low to put it into sleep mode.
Current Limit Setting:
- Adjust the current limit by setting the appropriate voltage on the REF pin. The formula is ( I_{text} = frac{V_{text}}{0.014} ).
Protection Features:
- Ensure that thermal shutdown and under-voltage lockout features are functioning correctly by monitoring the respective thresholds.
Heat Dissipation:
- For optimal performance, ensure adequate heat dissipation, especially when operating at higher currents or temperatures.
Initialization:
- Before starting operation, initialize the device by setting up the necessary control signals and ensuring all connections are secure.