G4A-1A-E-12V G4A-1A-E-DC12V G4A-1A-E-12VDC 12V 20A 4PINS

G4A-1A-E-12V G4A-1A-E-DC12V G4A-1A-E-12VDC 12V 20A 4PINS


Specifications
SKU
12603925
Details

BUY G4A-1A-E-12V G4A-1A-E-DC12V G4A-1A-E-12VDC 12V 20A 4PINS https://www.utsource.net/itm/p/12603925.html

Parameter Value Description
Part Number G4A-1A-E-12V Relay Module
Voltage DC 12V Operating Voltage
Current Rating 20A Maximum Contact Current
Pin Configuration 4 Pins Number of Connection Pins
Coil Resistance 120惟 Resistance of the Coil
Operating Time 10ms (max) Time to Operate
Release Time 5ms (max) Time to Release
Mechanical Life 10 million cycles Expected Mechanical Operations
Electrical Life 100,000 cycles Expected Electrical Operations (at rated load)
Insulation Resistance 100M惟 (min) Minimum Insulation Resistance
Dielectric Strength 1500V AC (min) Minimum Dielectric Strength
Operating Temperature -40掳C to +85掳C Temperature Range for Operation
Storage Temperature -40掳C to +125掳C Temperature Range for Storage
Mounting Position Any Can be Mounted in Any Orientation
Terminal Type Quick Connect Type of Terminals
Weight 20g Approximate Weight

Instructions:

  1. Power Supply: Ensure the relay is powered by a DC 12V supply.
  2. Connection: Connect the relay to the circuit using the 4-pin configuration. Typically, the pins are labeled as follows:
    • Pin 1: Common (C)
    • Pin 2: Normally Open (NO)
    • Pin 3: Normally Closed (NC)
    • Pin 4: Coil Positive (+)
    • Ground: Coil Negative (-)
  3. Operation: When the coil is energized, the common contact (C) will switch from the normally closed (NC) position to the normally open (NO) position.
  4. Current Handling: Do not exceed the maximum contact current rating of 20A to avoid damage to the relay.
  5. Environmental Conditions: Ensure the relay operates within the specified temperature range (-40掳C to +85掳C) and is stored within the storage temperature range (-40掳C to +125掳C).
  6. Mounting: The relay can be mounted in any orientation due to its design.
  7. Inspection: Regularly inspect the relay for signs of wear or damage, especially if it is used in high-vibration environments.
  8. Safety: Always disconnect power before making any connections or performing maintenance on the relay.
(For reference only)