Details
BUY HCPL-3150 https://www.utsource.net/itm/p/12604134.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Input Current | I(F) | - | 0.75 | 1.25 | mA | V(I) = 1.2V, V(O) = 4.5V |
| Forward Voltage | V(F) | 1.1 | 1.3 | 1.5 | V | I(F) = 20mA |
| Isolation Voltage | VIORM | - | 2500 | - | Vrms | Continuous |
| Propagation Delay Time | tPLH, tPHL | 1.5 | 3.5 | 6 | 渭s | V(I) = 1.2V, V(O) = 4.5V, I(F) = 1mA |
| CTR (Current Transfer Ratio) | CTR | 50 | 150 | 300 | % | I(F) = 5mA |
| Operating Temperature | Topr | -40 | - | 85 | 掳C | Storage Temperature |
| Storage Temperature | Tstg | -55 | - | 125 | 掳C | - |
Instructions for HCPL-3150:
- Power Supply: Ensure that the input and output voltages are within specified limits to avoid damage.
- Input Current: The device operates optimally with an input current between 0.75mA and 1.25mA. Adjust your circuit to maintain this range.
- Isolation Voltage: For safety and proper operation, do not exceed the maximum isolation voltage of 2500Vrms continuously.
- Propagation Delay: Account for a propagation delay between 1.5渭s and 6渭s in timing-sensitive applications.
- Temperature Considerations: Operate within the temperature range of -40掳C to 85掳C for optimal performance. Storage should be between -55掳C and 125掳C.
- CTR Variation: Expect variations in Current Transfer Ratio which can affect signal strength. Design circuits to accommodate CTR from 50% to 300%.
- Handling Precautions: Handle the device carefully to prevent electrostatic discharge (ESD) damage. Use appropriate ESD protection measures during assembly and handling.
View more about HCPL-3150 on main site