KSD301 B130 130掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs)

KSD301 B130 130掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs)


Specifications
SKU
12604439
Details

BUY KSD301 B130 130掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs) https://www.utsource.net/itm/p/12604439.html

Parameter Value
Model KSD301 B130
Type Temperature Control Switch
Function Normally Closed (NC)
Trip Temperature 130掳C
Reset Temperature Approximately 90掳C
Contact Form SPST-NC (Single Pole Single Throw - Normally Closed)
Contact Rating 6A @ 250VAC
Life Cycle 10,000 cycles minimum
Operating Temperature -40掳C to 130掳C
Housing Material Phenolic resin
Mounting Type Snap-in or screw mount
Dimensions 17mm x 17mm x 17mm
Weight 5g
Certifications UL, CSA, CE, RoHS

Instructions for Use

  1. Installation:

    • Ensure the thermostat is installed in a location where it will accurately sense the temperature of the device or environment.
    • For snap-in mounting, align the thermostat with the designated hole and press firmly until it clicks into place.
    • For screw mounting, use the provided screws to secure the thermostat to the mounting surface.
  2. Wiring:

    • Connect the common terminal (COM) to the power supply.
    • Connect the normally closed (NC) terminal to the load or device being controlled.
    • Ensure all connections are secure and insulated to prevent short circuits.
  3. Operation:

    • When the temperature reaches 130掳C, the switch will open, breaking the circuit and turning off the connected device.
    • As the temperature cools down to approximately 90掳C, the switch will reset and close, restoring power to the device.
  4. Maintenance:

    • Regularly inspect the thermostat for signs of wear or damage.
    • Clean the thermostat and surrounding area to ensure proper temperature sensing.
    • Replace the thermostat if it fails to operate correctly or if it has reached its life cycle limit.
  5. Precautions:

    • Do not exceed the maximum contact rating (6A @ 250VAC).
    • Avoid exposing the thermostat to temperatures outside its operating range.
    • Do not modify the thermostat as this may void warranties and certifications.
    • Store the thermostat in a dry, cool place when not in use.
(For reference only)

View more about KSD301 B130 130掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs) on main site