Details
BUY HCPL-J312-300E https://www.utsource.net/itm/p/12604446.html
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Forward Voltage (LED) | VF | 1.1 | 1.35 | 1.6 | V |
| Reverse Voltage (LED) | VR | - | - | 5 | V |
| Forward Current (LED) | IF | - | 20 | 50 | mA |
| Peak Pulse Forward Current (LED) | IFp | - | - | 100 | mA |
| Reverse Leakage Current (LED) | IR | - | - | 100 | nA |
| Output Collector-Emitter Saturation Voltage | VCE(sat) | 0.4 | 0.7 | 1.0 | V |
| Output Collector Current | IC | - | 1.0 | 1.5 | A |
| Output Turn-On Time | ton | - | 1.5 | 2.0 | 渭s |
| Output Turn-Off Time | toff | - | 0.8 | 1.0 | 渭s |
| Isolation Voltage (RMS) | VIORMS | - | - | 3750 | VRMS |
| Operating Temperature Range | TA | -40 | - | 105 | 掳C |
| Storage Temperature Range | TSTG | -65 | - | 150 | 掳C |
Instructions for Use:
Power Supply:
- Ensure that the forward voltage (VF) is within the specified range to avoid damaging the LED.
- The reverse voltage (VR) should not exceed 5V to prevent breakdown.
Current Limiting:
- Use a current-limiting resistor to ensure the forward current (IF) does not exceed 50mA.
- For peak pulse applications, ensure the peak pulse forward current (IFp) does not exceed 100mA.
Output Configuration:
- The output collector-emitter saturation voltage (VCE(sat)) should be considered when designing the load circuit to ensure proper operation.
- The output collector current (IC) should not exceed 1.5A to avoid overheating or damage.
Timing Considerations:
- The output turn-on time (ton) and turn-off time (toff) should be taken into account for high-speed switching applications.
Isolation:
- The isolation voltage (VIORMS) is rated for 3750VRMS, providing robust electrical isolation between the input and output sides.
Temperature Management:
- Operate the device within the specified temperature ranges to ensure reliable performance.
- Store the device in a controlled environment to prevent damage from extreme temperatures.
Handling:
- Handle the device with care to avoid mechanical stress or damage to the leads.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage to the sensitive components.
View more about HCPL-J312-300E on main site