| Parameter | Description | Value | Unit |
|---|---|---|---|
| Input Voltage (VIN) | Minimum input voltage | 4.5 | V |
| Maximum input voltage | 60 | V | |
| Output Voltage (VOUT) | Adjustable output voltage range | 1.23 to 60 | V |
| Switching Frequency | Internal oscillator frequency | 270 | kHz |
| Peak Current Limit | Peak current limit of the switch | 2.5 | A |
| Quiescent Current | Supply current in regulation | 2.7 | mA |
| Shutdown Current | Supply current in shutdown mode | 1 | 渭A |
| Operating Temperature | Junction temperature range | -40 to +85 | 掳C |
| Package Type | IC package type | SOIC-8 |
Instructions for HIP2500IB:
Input Voltage Setup:
- Ensure the input voltage is within the specified range (4.5V to 60V).
Output Voltage Configuration:
- Use an external resistor divider to set the desired output voltage within the adjustable range (1.23V to 60V).
Switching Frequency Adjustment:
- The switching frequency is internally set to 270kHz and typically does not require adjustment.
Current Limiting:
- The device has a built-in peak current limit of 2.5A to protect against overload conditions.
Thermal Considerations:
- Operate within the junction temperature range (-40掳C to +85掳C). Ensure adequate heat dissipation if operating near the upper temperature limit.
Power-On Reset:
- The device includes a power-on reset circuit that ensures proper initialization when power is applied.
Shutdown Mode:
- To enter shutdown mode, pull the shutdown pin low. This reduces the supply current to approximately 1渭A.
PCB Layout Recommendations:
- Place the input capacitor close to the VIN pin.
- Keep the ground connections short and direct to minimize noise.
- Use wide traces for high current paths to reduce resistive losses.
Component Selection:
- Choose capacitors and inductors with ratings suitable for the maximum expected voltage and current levels.
Safety Precautions:
- Always use appropriate protective equipment when handling high voltages.
- Ensure all connections are secure to prevent shorts or intermittent contacts.