Details
BUY PS219C4-AST https://www.utsource.net/itm/p/12604534.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Component Identifier | PS219C4-AST |
| Type | Device Type | Photocoupler |
| Isolation Voltage | Maximum Isolation Voltage (VIORM) | 5000 Vrms |
| Forward Current | Maximum Forward Current (IF) | 60 mA |
| Reverse Voltage | Maximum Reverse Voltage (VR) | 5 V |
| Collector-Emitter Voltage | Maximum Collector-Emitter Voltage (VCE) | 70 V |
| Collector Current | Maximum Collector Current (IC) | 50 mA |
| Power Dissipation | Maximum Power Dissipation (PD) | 350 mW |
| Operating Temperature | Operating Temperature Range (Topr) | -40掳C to 110掳C |
| Storage Temperature | Storage Temperature Range (Tstg) | -40掳C to 125掳C |
| Rise Time | Typical Rise Time (tr) | 1 渭s |
| Fall Time | Typical Fall Time (tf) | 1 渭s |
| Current Transfer Ratio | Minimum Current Transfer Ratio (CTR) at IF = 5 mA, VCE = 5 V | 50% |
| Package Type | Package Style | SOP-4 |
| Pin Configuration | Pin Assignment | 1: Anode, 2: Cathode, 3: Emitter, 4: Collector |
Instructions for Use:
Mounting and Handling:
- Handle the device with care to avoid mechanical damage.
- Ensure proper alignment during mounting to prevent short circuits or incorrect connections.
Electrical Connections:
- Connect the anode (pin 1) to the positive side of the input circuit.
- Connect the cathode (pin 2) to the negative side of the input circuit.
- Connect the emitter (pin 3) to the ground of the output circuit.
- Connect the collector (pin 4) to the load and the positive side of the output circuit.
Operating Conditions:
- Ensure that the forward current (IF) does not exceed 60 mA to prevent damage to the LED.
- Keep the collector-emitter voltage (VCE) below 70 V to avoid breakdown.
- Operate the device within the temperature range of -40掳C to 110掳C to ensure reliable performance.
Storage:
- Store the device in a dry, cool place within the temperature range of -40掳C to 125掳C.
Testing:
- Use a multimeter to check the continuity and resistance values between the pins to ensure the device is functioning correctly.
- Measure the current transfer ratio (CTR) under typical operating conditions to verify performance.
Safety:
- Always follow safety guidelines when handling high voltages and currents.
- Use appropriate protective equipment and follow all relevant standards and regulations.
View more about PS219C4-AST on main site