Parameter Symbol Min Typical Max Unit Notes
Supply Voltage Vcc 4.5 - 30 V
Continuous Current Ic - 2.5 5 A @ Ta=25掳C
Peak Current Icp - 5 10 A 10ms pulse, @ Ta=25掳C
Control Input Voltage Vin 0 - 5 V
Control Input Current Iin 0 1.5 3 mA
Thermal Resistance Rth - 25 - 掳C/W Junction to Ambient
Operating Temperature Topr -40 - 85 掳C
Storage Temperature Tstg -40 - 125 掳C

Instructions for Use:

  1. Supply Voltage (Vcc):

    • Ensure the supply voltage is within the range of 4.5V to 30V.
    • Exceeding the maximum voltage can damage the device.
  2. Continuous Current (Ic):

    • The continuous current should not exceed 5A at 25掳C ambient temperature.
    • For higher ambient temperatures, derate the current to avoid overheating.
  3. Peak Current (Icp):

    • The peak current can be up to 10A for short pulses (10ms) at 25掳C ambient temperature.
    • Ensure the pulse duration does not exceed 10ms to prevent thermal damage.
  4. Control Input Voltage (Vin):

    • The control input voltage should be between 0V and 5V.
    • Use a logic level signal to control the device.
  5. Control Input Current (Iin):

    • The control input current should be between 0mA and 3mA.
    • Ensure the driving circuit can provide this current.
  6. Thermal Management:

    • The thermal resistance from junction to ambient is 25掳C/W.
    • Use a heatsink if the device will operate at high currents or in high ambient temperatures.
  7. Operating Temperature (Topr):

    • The device is designed to operate between -40掳C and 85掳C.
    • Avoid operating outside this range to ensure reliable performance.
  8. Storage Temperature (Tstg):

    • Store the device between -40掳C and 125掳C.
    • Avoid exposing the device to extreme temperatures for extended periods.
  9. Mounting and Handling:

    • Handle the device with care to avoid mechanical stress.
    • Follow proper soldering techniques to ensure a reliable connection.
  10. Safety Precautions:

    • Always use appropriate safety measures when working with electrical components.
    • Ensure proper grounding and insulation to prevent electrical shock.
(For reference only)