KSD301 B125 125掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs)
Category: Elec-componentIC ChipsTemperature Sensor
Specifications
SKU
12604988
Details
BUY KSD301 B125 125掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs) https://www.utsource.net/itm/p/12604988.html
Parameter | Value |
---|---|
Type | Temperature Control Switch |
Model | KSD301 B125 |
Operating Temperature | 125掳C |
Contact Type | Normally Closed (NC) |
Action Type | Jump Type |
Contact Rating | 16A, 250VAC / 10A, 125VDC |
Differential Temperature | 5-15掳C |
Mounting Method | Snap Action, Surface Mount |
Terminal Type | Quick Connect (2.8mm) |
Insulation Resistance | >100M惟 at 500VDC |
Dielectric Strength | 1500VAC for 1 minute |
Mechanical Life | 10,000 cycles |
Electrical Life | 5,000 cycles |
Weight | 4g |
Dimensions | 10.2mm x 10.2mm x 9.5mm |
Operating Humidity | 5% to 95% RH (non-condensing) |
Storage Temperature | -40掳C to 150掳C |
Packaging | 5pcs per pack |
Instructions
Installation:
- Ensure the thermostat is installed in a location where it can accurately sense the temperature of the device or environment.
- Use the quick connect terminals to secure the wires. Ensure a firm connection to avoid any loose connections.
Mounting:
- The KSD301 B125 can be surface mounted. Ensure the mounting surface is clean and flat.
- Use appropriate mounting hardware to secure the thermostat in place.
Wiring:
- Connect the normally closed (NC) contacts to the circuit you want to control.
- When the temperature reaches 125掳C, the switch will open, breaking the circuit.
- As the temperature drops, the switch will reset and close the circuit within a differential range of 5-15掳C.
Testing:
- Before final installation, test the thermostat to ensure it operates correctly.
- Apply a controlled heat source to the thermostat and verify that the switch opens at 125掳C and closes as the temperature decreases.
Maintenance:
- Regularly inspect the thermostat for signs of wear or damage.
- Clean the thermostat with a soft, dry cloth to remove dust and debris.
Safety:
- Do not exceed the maximum operating temperature of 125掳C.
- Ensure the electrical connections are rated for the current and voltage specified.
- Do not use the thermostat in environments with explosive gases or flammable materials.
Storage:
- Store the thermostats in a dry, cool place away from direct sunlight and extreme temperatures.
- Keep the thermostats in their original packaging until ready for use.
Disposal:
- Dispose of the thermostat in accordance with local environmental regulations.
View more about KSD301 B125 125掳C Normally Close Jump type Temperature Control Switch Thermostats (5pcs) on main site