Details
BUY MXP4002AT https://www.utsource.net/itm/p/12605184.html
Below is the parameter table and instructions for the MXP4002AT, a pressure sensor.
MXP4002AT Parameter Table
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage | VDD | 2.7 | 5.0 | 5.5 | V |
| Operating Temperature Range | -40 | 125 | 掳C | ||
| Pressure Range | 0 | 100 | kPa | ||
| Output Signal | VOUT | 0.06 | 4.94 | 5.00 | V |
| Sensitivity | S | 48 | 50 | 52 | mV/kPa |
| Non-Linearity | NL | -0.2 | 0 | 0.2 | %FSO |
| Hysteresis | HYST | -0.1 | 0 | 0.1 | %FSO |
| Temperature Coefficient of Zero | TCZ | -0.03 | 0 | 0.03 | %FSO/掳C |
| Temperature Coefficient of Span | TCS | -0.03 | 0 | 0.03 | %FSO/掳C |
| Input Impedance | Zin | 10 | 10 | 10 | k惟 |
| Output Impedance | Zout | 1.0 | 1.0 | 1.0 | k惟 |
| Bandwidth | BW | 0 | 100 | 1000 | Hz |
Instructions for Using MXP4002AT
Power Supply:
- Connect the supply voltage (VDD) to the positive terminal of the sensor.
- Ensure the supply voltage is within the range of 2.7V to 5.5V.
- Ground the negative terminal (GND).
Signal Output:
- The output signal (VOUT) will vary linearly with the applied pressure.
- The typical output range is from 0.06V to 4.94V for a pressure range of 0 to 100 kPa.
- Connect the output signal to your measurement or control system.
Temperature Considerations:
- The sensor is designed to operate within a temperature range of -40掳C to 125掳C.
- Be aware of the temperature coefficient of zero (TCZ) and span (TCS) which can affect the accuracy of the readings.
Calibration:
- For high-precision applications, calibrate the sensor using known pressure points.
- Use the sensitivity (S) and non-linearity (NL) parameters to adjust the readings.
Mounting:
- Mount the sensor in a location where it is not subjected to mechanical stress or vibration.
- Ensure the pressure port is aligned correctly with the pressure source.
Electrical Connections:
- Use shielded cables to minimize noise interference.
- Keep the leads short to reduce signal degradation.
Storage and Handling:
- Store the sensor in a dry, clean environment.
- Handle the sensor with care to avoid damaging the sensitive components.
By following these instructions, you can ensure optimal performance and reliability of the MXP4002AT pressure sensor.
(For reference only)View more about MXP4002AT on main site