Details
BUY SFH6705 https://www.utsource.net/itm/p/12605701.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Forward Current | IF | - | 10 | 100 | mA | Maximum continuous forward current at Ta = 25°C |
| Reverse Voltage | VR | - | - | 5 | V | Maximum reverse voltage |
| Forward Voltage | VF | 1.2 | 1.4 | 1.8 | V | Forward voltage at IF = 20 mA |
| Peak Wavelength | λp | 870 | - | - | nm | Peak emission wavelength |
| Spectral Width | Δλ | - | 40 | - | nm | Full width at half maximum (FWHM) |
| Radiant Intensity | Iv | 20 | - | - | mW/sr | Typical radiant intensity at IF = 100 mA |
| Viewing Angle | θ1/2 | - | 15 | - | ° | Half-intensity angle |
| Operating Temperature | Topr | -40 | - | 100 | °C | Operating temperature range |
| Storage Temperature | Tstg | -40 | - | 125 | °C | Storage temperature range |
| Moisture Sensitivity Level | MSL | - | 3 | - | Level | Moisture sensitivity level according to J-STD-020 |
Instructions for Use:
Handling:
- Handle with care to avoid mechanical damage.
- Avoid touching the active area with bare hands.
Mounting:
- Ensure proper heat sinking if operating at high currents.
- Use recommended soldering profiles to prevent thermal shock.
Electrical Connections:
- Connect the anode (A) to the positive supply and the cathode (K) to the ground.
- Do not exceed the maximum forward current (IF) and reverse voltage (VR) ratings.
Environmental Considerations:
- Operate within the specified temperature range to ensure reliable performance.
- Store in a dry environment to prevent moisture damage.
Testing:
- Use a constant current source to test the device.
- Measure the forward voltage (VF) at a specified forward current (IF).
Safety:
- Follow all relevant safety guidelines when handling and testing the device.
- Dispose of the device according to local regulations.
View more about SFH6705 on main site