TJA1050

TJA1050


Specifications
SKU
12606007
Details

BUY TJA1050 https://www.utsource.net/itm/p/12606007.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.75 5.0 5.25 V
Standby Current ICC(standby) VCC = 5V, STBY = High - 35 60 渭A
Operating Current ICC(operating) VCC = 5V, STBY = Low 8 15 25 mA
Output Voltage Swing VOSWING VCC = 5V, RL = 120惟 0.5 1.5 2.5 V
Differential Input Voltage Range VIDIFF Continuous -25 - 25 V
Common-Mode Input Voltage Range VICM Continuous -2 - 7 V
Maximum Data Rate fDATA - - 1 2 Mbps
Thermal Shutdown Temperature TSD - - 150 - 掳C
Operating Temperature Range TA - -40 - 125 掳C
Storage Temperature Range TSTG - -40 - 150 掳C

Instructions for Using TJA1050

  1. Power Supply:

    • Connect the VCC pin to a 5V supply.
    • Ensure the supply voltage is within the range of 4.75V to 5.25V to avoid damage.
  2. Standby Mode:

    • Set the STBY pin to a high level (VCC) to enter standby mode, reducing power consumption.
    • Set the STBY pin to a low level (GND) to activate the device for normal operation.
  3. Differential Inputs:

    • Connect the differential input pins (CANH and CANL) to the CAN bus.
    • Ensure the common-mode input voltage (VICM) stays within the range of -2V to 7V to prevent damage.
  4. Output Configuration:

    • The output pins (TXD and RXD) should be connected to the microcontroller or other communication interface.
    • The output voltage swing (VOSWING) is designed to work with a 120惟 load.
  5. Data Rate:

    • The TJA1050 supports data rates up to 1 Mbps, with a maximum of 2 Mbps under optimal conditions.
  6. Thermal Management:

    • Monitor the temperature to ensure it does not exceed 150掳C, which can trigger thermal shutdown.
    • Use appropriate heat sinks or cooling methods if operating in high-temperature environments.
  7. Environmental Considerations:

    • Operate the device within the temperature range of -40掳C to 125掳C.
    • Store the device within the temperature range of -40掳C to 150掳C to avoid degradation.
  8. Electrostatic Discharge (ESD) Protection:

    • Handle the device with proper ESD precautions to avoid damage.
    • Use ESD-protected workstations and tools when handling the TJA1050.
  9. Signal Integrity:

    • Use proper termination resistors (120惟) on the CAN bus to minimize reflections and ensure reliable communication.
    • Keep signal traces as short as possible to reduce noise and interference.

By following these instructions, you can ensure the TJA1050 operates reliably and efficiently in your application.