Details
BUY BCR10PM-12L https://www.utsource.net/itm/p/12606018.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Full part number of the component | BCR10PM-12L |
| Type | Type of component | Power MOSFET |
| Package | Package type | TO-252 (DPAK) |
| Polarity | Polarity of the device | N-Channel |
| VDS | Drain-to-Source Voltage | 12 V |
| VGS | Gate-to-Source Voltage | 卤20 V |
| ID | Continuous Drain Current | 10 A |
| RDS(on) | On-State Resistance at VGS = 4.5 V, ID = 5 A | 1.2 m惟 |
| Power Dissipation | Maximum Power Dissipation (at TA = 25掳C) | 60 W |
| Operating Temperature Range | Junction Temperature (TJ) | -55掳C to +175掳C |
| Storage Temperature Range | Storage Temperature (TSTG) | -65掳C to +150掳C |
| Thermal Resistance | Junction-to-Ambient (R胃JA) | 62 掳C/W |
| Gate Charge | Total Gate Charge | 13 nC |
| Input Capacitance | Input Capacitance (Ciss) at VDS = 10 V, f = 1 MHz | 1100 pF |
| Output Capacitance | Output Capacitance (Coss) at VDS = 10 V, f = 1 MHz | 180 pF |
| Reverse Transfer Capacitance | Reverse Transfer Capacitance (Crss) at VDS = 10 V, f = 1 MHz | 220 pF |
Instructions for Use:
Handling Precautions:
- ESD Protection: The BCR10PM-12L is sensitive to electrostatic discharge (ESD). Use appropriate ESD protection measures during handling and assembly.
- Soldering Temperature: Ensure that the soldering temperature does not exceed 260掳C for more than 10 seconds to avoid damaging the device.
Mounting:
- Heatsinking: For applications where the power dissipation is high, use a heatsink to maintain the junction temperature within the specified range.
- Orientation: Ensure the correct orientation of the device during mounting to avoid incorrect connections.
Biasing:
- Gate Drive: Apply the gate voltage within the specified range to ensure reliable operation. Avoid exceeding the maximum gate-to-source voltage to prevent damage.
- Source Connection: Ensure a low-inductance path between the source terminal and the circuit ground to minimize switching losses and parasitic oscillations.
Operational Considerations:
- Overcurrent Protection: Implement overcurrent protection to prevent damage due to excessive drain current.
- Thermal Management: Monitor the junction temperature and ensure it remains within the operating limits to maintain long-term reliability.
Testing:
- Initial Testing: Perform initial testing under controlled conditions to verify the performance parameters.
- Periodic Testing: Conduct periodic testing to ensure the device continues to meet the specified performance criteria.
Storage:
- Environmental Conditions: Store the device in a dry, cool environment to prevent moisture absorption and degradation.
- Packaging: Keep the device in its original packaging until ready for use to protect against physical damage and ESD.
For detailed application notes and further technical information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about BCR10PM-12L on main site