Details
BUY IPA60R280P7S https://www.utsource.net/itm/p/12606022.html
| Parameter | Symbol | Test Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Continuous Drain Current | ID | VGS = 10V, TA = 25掳C | - | 330 | - | A |
| Pulse Drain Current | ID pul | VGS = 10V, tp = 10ms, TC = 25掳C | - | 550 | - | A |
| Gate-Source Voltage | VGS | - | -20 | 0 | 20 | V |
| Drain-Source Breakdown Voltage | VDS(off) | ID = 250渭A, IG = 0mA | 600 | - | - | V |
| On-State Resistance | RDS(on) | VGS = 10V, ID = 330A, TA = 25掳C | - | 280 | - | m惟 |
| Gate Charge | QG | VGS = 15V, IG = 1A | - | 220 | - | nC |
| Input Capacitance | Ciss | VDS = 450V, f = 1MHz | - | 2400 | - | pF |
| Output Capacitance | Coss | VDS = 450V, f = 1MHz | - | 220 | - | pF |
| Reverse Transfer Capacitance | Crss | VDS = 450V, ID = 1A, f = 1MHz | - | 220 | - | pF |
| Total Switching Energy | Esw | VDS = 450V, ID = 330A, fsw = 100kHz | - | 1.9 | - | mJ |
| Thermal Resistance (Junction to Case) | Rth(j-c) | - | - | 0.25 | - | 掳C/W |
| Junction Temperature | TJ | - | - | 175 | - | 掳C |
| Storage Temperature Range | TSTG | - | -65 | - | 150 | 掳C |
Instructions for Use:
Handling and Storage:
- Store the device in a dry, cool place.
- Handle with care to avoid mechanical damage and static discharge.
Mounting:
- Ensure proper heat sinking to maintain junction temperature within specified limits.
- Use recommended torque values for screw terminals to avoid over-tightening or under-tightening.
Electrical Connections:
- Connect the gate and source terminals carefully to avoid short circuits.
- Use low inductance gate drive circuits to minimize switching losses.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 175掳C.
- Use thermal paste or thermal interface materials between the device and heat sink for better thermal conductivity.
Operational Parameters:
- Do not exceed the maximum ratings for drain-source voltage, gate-source voltage, and continuous drain current.
- Ensure the gate drive voltage is within the specified range to avoid damage to the device.
Testing:
- Perform initial testing at room temperature and gradually increase the load to ensure stable operation.
- Regularly check the device parameters during operation to ensure they remain within the specified limits.
Safety Precautions:
- Always use appropriate safety equipment when handling high-voltage circuits.
- Follow all relevant safety standards and guidelines for high-power electronics.
By adhering to these instructions, you can ensure reliable and efficient operation of the IPA60R280P7S MOSFET.
(For reference only)View more about IPA60R280P7S on main site