Details
BUY FS2VS-18 https://www.utsource.net/itm/p/12606058.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Full Part Number | FS2VS-18 |
| Type | Switch Type | SPDT (Single Pole, Double Throw) |
| Mounting | Mounting Style | Surface Mount |
| Contact Form | Contact Configuration | 1NO + 1NC |
| Actuator | Actuator Type | Slider |
| Operating Force | Operating Force (Typical) | 0.5N |
| Contact Material | Contact Material | Gold Plated |
| Contact Resistance | Contact Resistance (Max) | 50m惟 |
| Insulation Resistance | Insulation Resistance (Min) | 100M惟 |
| Dielectric Withstand Voltage | Dielectric Withstand Voltage | 500V AC RMS |
| Operating Temperature | Operating Temperature Range | -40掳C to 85掳C |
| Storage Temperature | Storage Temperature Range | -55掳C to 125掳C |
| Operating Humidity | Operating Humidity Range | 5% to 95% RH |
| Life Cycle | Mechanical Life (Min) | 100,000 cycles |
| Electrical Life | Electrical Life (Min) | 50,000 cycles |
| Termination | Termination Type | Solder |
| RoHS Compliance | RoHS Compliant | Yes |
| Package Quantity | Package Quantity | 1000 per reel |
Instructions for Use
Handling and Storage:
- Store the switches in a dry, cool environment with a temperature range of -55掳C to 125掳C and humidity between 5% and 95% RH.
- Handle the switches with care to avoid damage to the contacts or actuator.
Mounting:
- Ensure the PCB is clean and free of contaminants before mounting the switch.
- Use a soldering iron with a temperature setting appropriate for surface mount components (typically 300掳C to 350掳C).
- Apply solder to the pads and place the switch carefully to avoid misalignment.
- Inspect the solder joints for proper wetting and avoid excessive solder to prevent short circuits.
Operation:
- The switch is designed for manual operation using the slider actuator.
- Apply the operating force (0.5N typical) to the actuator to switch between the NO (Normally Open) and NC (Normally Closed) contacts.
- Do not exceed the mechanical life of 100,000 cycles or the electrical life of 50,000 cycles to ensure reliable performance.
Testing:
- Test the switch for continuity between the contacts using a multimeter.
- Verify that the contact resistance does not exceed 50m惟 and the insulation resistance is at least 100M惟.
- Perform a dielectric withstand test at 500V AC RMS to ensure the switch can handle the specified voltage.
Disposal:
- Dispose of the switch according to local regulations and guidelines for electronic waste.
- If the switch is RoHS compliant, it should be handled as per the RoHS directive for disposal and recycling.
View more about FS2VS-18 on main site