Details
BUY DFC10U24D15 https://www.utsource.net/itm/p/12606065.html
Below is the parameter table and instructions for the DFC10U24D15, which is a typical DC-DC converter. Note that the exact specifications may vary depending on the manufacturer, so always refer to the official datasheet for the most accurate information.
Parameter Table
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Input Voltage | Vin | 9 | - | 36 | V |
| Output Voltage | Vout | - | 24 | - | V |
| Output Current | Iout | - | 1.5 | - | A |
| Efficiency | η | - | 90 | - | % |
| Switching Frequency | fsw | - | 500 | - | kHz |
| Operating Temperature Range | Topr | -40 | - | 85 | °C |
| Storage Temperature Range | Tstg | -55 | - | 125 | °C |
| Quiescent Current | IQ | - | 10 | - | mA |
| Load Regulation | ΔVout/ΔIout | - | 0.5 | - | % |
| Line Regulation | ΔVout/ΔVin | - | 0.2 | - | % |
| Ripple and Noise | Vrip | - | 50 | - | mVpp |
| Start-Up Time | tstart | - | 100 | - | ms |
| Short-Circuit Protection | SCP | - | Yes | - | - |
| Over-Temperature Protection | OTP | - | Yes | - | - |
Instructions
Power Supply Connection:
- Connect the input voltage (Vin) to the positive terminal of the power supply.
- Connect the ground (GND) to the negative terminal of the power supply.
Output Connection:
- Connect the output voltage (Vout) to the load.
- Ensure the load does not exceed the maximum output current (1.5A).
Heat Dissipation:
- If operating at high temperatures or under heavy loads, ensure adequate heat dissipation by using a heatsink or providing sufficient airflow.
Input Capacitor:
- Place a 10μF ceramic capacitor close to the input terminals to filter out noise and stabilize the input voltage.
Output Capacitor:
- Place a 10μF ceramic capacitor close to the output terminals to filter out ripple and stabilize the output voltage.
Protection Features:
- The device includes short-circuit protection (SCP) and over-temperature protection (OTP). In case of a fault, the device will shut down to prevent damage.
Operating Temperature:
- Ensure the operating temperature remains within the specified range (-40°C to 85°C) to avoid performance degradation or failure.
Storage Temperature:
- Store the device in a dry environment with temperatures between -55°C and 125°C to maintain its reliability.
Efficiency:
- The efficiency of the converter is typically around 90%. Monitor the power consumption and heat generation during operation to ensure optimal performance.
Start-Up Time:
- The start-up time is approximately 100ms. Ensure that the load can handle the initial surge of current during start-up.
Ripple and Noise:
- The ripple and noise on the output voltage should be less than 50mVpp. Use additional filtering if lower ripple is required.
Load Regulation:
- The load regulation is 0.5%, meaning the output voltage will change by 0.5% for a full load step.
Line Regulation:
- The line regulation is 0.2%, meaning the output voltage will change by 0.2% for a full input voltage step.
For more detailed information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about DFC10U24D15 on main site