Details
BUY MMD70R600PRH https://www.utsource.net/itm/p/12606089.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | - | 2.0 | - | V | @ IF = 20 A, TJ = 25掳C |
| Reverse Blocking Voltage | VBR | - | 600 | - | V | @ IR = 1 mA, TJ = 25掳C |
| Continuous Forward Current | IF | - | 70 | - | A | @ TC = 25掳C |
| Pulse Forward Current | IFsm | - | 350 | - | A | tp = 10 ms, TJ = 25掳C |
| Reverse Recovery Time | trr | - | 75 | - | ns | @ IF = 70 A, di/dt = 100 A/渭s |
| Junction Temperature | TJ | - | - | 175 | 掳C | Maximum |
| Storage Temperature | Tstg | -40 | - | 150 | 掳C |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within safe limits.
- Use appropriate mounting torque to ensure good thermal contact.
Electrical Connections:
- Connect the device according to the polarity markings on the package.
- Use short, low-inductance leads to minimize parasitic inductance.
Thermal Management:
- Monitor the junction temperature to avoid exceeding the maximum rating.
- Consider forced air cooling or liquid cooling for high-power applications.
Surge Handling:
- The device can handle pulse currents up to 350 A for short durations (10 ms). Ensure that the pulse duration and frequency do not exceed these limits.
Reverse Recovery:
- Be aware of the reverse recovery time when designing circuits to avoid excessive voltage spikes during switching.
Storage:
- Store the device in a dry, cool environment to prevent moisture damage.
- Handle with care to avoid mechanical stress or damage to the leads.
Testing:
- Perform initial testing at lower current levels to verify correct operation before moving to full load conditions.
- Use appropriate test equipment to measure parameters accurately.
Safety:
- Always follow safety guidelines when handling high-voltage and high-current components.
- Use protective equipment such as gloves and safety glasses when necessary.