| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating Range | 2.0 | - | 5.5 | V |
| Input Low Voltage | VI(L) | VCC = 5.5V | -0.5 | - | 1.5 | V |
| Input High Voltage | VI(H) | VCC = 5.5V | 3.5 | - | 6.0 | V |
| Output Low Voltage | VO(L) | IOL = 16 mA, VCC = 5.5V | -0.5 | - | 0.4 | V |
| Output High Voltage | VO(H) | IOH = -4 mA, VCC = 5.5V | 4.1 | - | 5.5 | V |
| Input Leakage Current | II | VI = 0V or VCC | - | 卤1 | - | 渭A |
| Output Leakage Current | IOZ | VI = 0V or VCC | - | 卤50 | - | nA |
| Propagation Delay Time | tpd | VCC = 5.5V, TA = 25掳C | - | 4.8 | - | ns |
| Power Dissipation | PD | VCC = 5.5V, TA = 25掳C | - | - | 150 | mW |
| Operating Temperature Range | Toper | - | -40 | - | 85 | 掳C |
| Storage Temperature Range | Tstg | - | -65 | - | 150 | 掳C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the specified range of 2.0V to 5.5V.
- Connect VCC to the positive power supply and GND to the ground.
Input Signals:
- Apply input signals (VI) that meet the specified input low (VI(L)) and high (VI(H)) voltage levels.
- Avoid exceeding the maximum input voltage to prevent damage to the device.
Output Signals:
- The output signals (VO) will be driven to the specified output low (VO(L)) and high (VO(H)) voltage levels.
- Ensure the load connected to the output can handle the specified current levels (IOL and IOH).
Leakage Current:
- Be aware of the input and output leakage currents (II and IOZ) to ensure proper circuit design and minimize unwanted effects.
Timing:
- Consider the propagation delay time (tpd) when designing circuits to ensure proper timing and synchronization.
Temperature:
- Operate the device within the specified operating temperature range (Toper) to ensure reliable performance.
- Store the device within the specified storage temperature range (Tstg) to prevent damage.
Power Dissipation:
- Ensure the power dissipation (PD) does not exceed the maximum rating to avoid overheating and potential damage.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.