74VHCT14PW

74VHCT14PW


Specifications
SKU
12606113
Details

BUY 74VHCT14PW https://www.utsource.net/itm/p/12606113.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating Range 2.0 - 5.5 V
Input Low Voltage VI(L) VCC = 5.5V -0.5 - 1.5 V
Input High Voltage VI(H) VCC = 5.5V 3.5 - 6.0 V
Output Low Voltage VO(L) IOL = 16 mA, VCC = 5.5V -0.5 - 0.4 V
Output High Voltage VO(H) IOH = -4 mA, VCC = 5.5V 4.1 - 5.5 V
Input Leakage Current II VI = 0V or VCC - 卤1 - 渭A
Output Leakage Current IOZ VI = 0V or VCC - 卤50 - nA
Propagation Delay Time tpd VCC = 5.5V, TA = 25掳C - 4.8 - ns
Power Dissipation PD VCC = 5.5V, TA = 25掳C - - 150 mW
Operating Temperature Range Toper - -40 - 85 掳C
Storage Temperature Range Tstg - -65 - 150 掳C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 2.0V to 5.5V.
    • Connect VCC to the positive power supply and GND to the ground.
  2. Input Signals:

    • Apply input signals (VI) that meet the specified input low (VI(L)) and high (VI(H)) voltage levels.
    • Avoid exceeding the maximum input voltage to prevent damage to the device.
  3. Output Signals:

    • The output signals (VO) will be driven to the specified output low (VO(L)) and high (VO(H)) voltage levels.
    • Ensure the load connected to the output can handle the specified current levels (IOL and IOH).
  4. Leakage Current:

    • Be aware of the input and output leakage currents (II and IOZ) to ensure proper circuit design and minimize unwanted effects.
  5. Timing:

    • Consider the propagation delay time (tpd) when designing circuits to ensure proper timing and synchronization.
  6. Temperature:

    • Operate the device within the specified operating temperature range (Toper) to ensure reliable performance.
    • Store the device within the specified storage temperature range (Tstg) to prevent damage.
  7. Power Dissipation:

    • Ensure the power dissipation (PD) does not exceed the maximum rating to avoid overheating and potential damage.
  8. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
(For reference only)

View more about 74VHCT14PW on main site