| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 8.5 | - | 20 | V | Operating supply voltage range |
| Logic Input Voltage | VIL | -0.3 | - | 1.3 | V | Input low level voltage |
| Logic Input Voltage | VIH | 2.0 | - | 5.5 | V | Input high level voltage |
| Output Current (Source) | IOUT(source) | - | 0.5 | 1.0 | A | Maximum output current (source) |
| Output Current (Sink) | IOUT(sink) | - | 1.0 | 2.0 | A | Maximum output current (sink) |
| Propagation Delay Time | td | 10 | - | 40 | ns | Propagation delay time from input to output |
| Rise Time | tr | - | 20 | 50 | ns | Rise time of output signal |
| Fall Time | tf | - | 20 | 50 | ns | Fall time of output signal |
| Operating Temperature Range | TOP | -40 | - | 125 | 掳C | Operating temperature range |
| Storage Temperature Range | TSTG | -65 | - | 150 | 掳C | Storage temperature range |
Instructions for Using IR21064S
Power Supply Connection:
- Connect the VCC pin to the power supply within the specified range (8.5V to 20V).
- Ensure a stable power supply to avoid voltage drops that could affect performance.
Logic Input:
- Apply logic levels to the input pins (IN) within the specified range (VIL: 0V to 1.3V, VIH: 2.0V to 5.5V).
- Use appropriate pull-up or pull-down resistors if necessary to ensure clean logic levels.
Output Configuration:
- The output pins (OUT) can source or sink current up to the maximum ratings.
- Ensure the load connected to the output does not exceed the maximum current ratings.
Timing Considerations:
- Be aware of the propagation delay (td), rise time (tr), and fall time (tf) to ensure proper timing in your application.
- Use these parameters to design appropriate timing circuits if needed.
Thermal Management:
- Operate the device within the specified temperature range (TOP: -40掳C to 125掳C).
- Provide adequate heat sinking if the device is expected to dissipate significant power.
Storage:
- Store the device in a dry environment within the storage temperature range (TSTG: -65掳C to 150掳C) to prevent damage.
Electrostatic Discharge (ESD) Protection:
- Handle the device with ESD precautions to avoid damage from static electricity.
- Use grounded wrist straps and ESD-safe workstations when handling the device.
Mounting:
- Follow the recommended PCB layout guidelines to ensure optimal performance and thermal management.
- Use appropriate soldering techniques to avoid thermal stress on the device during assembly.
View more about IR21064S on main site