Details
BUY MP3394S https://www.utsource.net/itm/p/12606228.html
Below is the parameter table and instructions for the MP3394S, a 4-Phase Buck Controller.
MP3394S Parameter Table
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 18 | V | Operating input voltage range |
| Output Voltage | VOUT | 0.6 | - | 1.8 | V | Adjustable output voltage range |
| Phase Current | IPHASE | - | 20 | - | A | Maximum phase current per channel |
| Switching Frequency | FSW | 300 | 500 | 700 | kHz | Adjustable switching frequency |
| Duty Cycle Range | D | 0 | - | 100 | % | Duty cycle range |
| Reference Voltage | VREF | 0.6 | - | 0.6 | V | Internal reference voltage |
| Enable Threshold | VEN | 0.8 | - | 1.2 | V | Enable pin threshold |
| UVLO Threshold | VUVLO | 3.0 | - | 3.5 | V | Under-voltage lockout threshold |
| OVP Threshold | VOV | 1.85 | - | 1.95 | V | Overvoltage protection threshold |
| Thermal Shutdown | TSD | 150 | - | 160 | °C | Thermal shutdown temperature |
| Operating Temperature | TOPR | -40 | - | 125 | °C | Operating temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
MP3394S Instructions
Power Supply Connection:
- Connect the input voltage (VIN) to the power supply.
- Ensure the input voltage is within the operating range (4.5V to 18V).
Output Configuration:
- Set the output voltage (VOUT) using external resistors connected to the FB pin.
- The output voltage can be adjusted from 0.6V to 1.8V.
Enable Pin:
- Connect the EN pin to a logic high (≥1.2V) to enable the controller.
- Connect the EN pin to a logic low (≤0.8V) to disable the controller.
Switching Frequency:
- Set the switching frequency (FSW) by connecting an external resistor to the RT pin.
- The typical switching frequency range is 300kHz to 700kHz.
Current Limit:
- The maximum phase current (IPHASE) is 20A per channel.
- Use appropriate inductors and MOSFETs to handle the current.
Protection Features:
- The controller includes under-voltage lockout (UVLO), overvoltage protection (OVP), and thermal shutdown (TSD).
- Ensure the UVLO threshold (3.0V to 3.5V) is not exceeded.
- The OVP threshold is set at 1.85V to 1.95V.
- The thermal shutdown temperature is 150°C to 160°C.
Thermal Management:
- Place the controller in a well-ventilated area or use a heatsink to manage heat dissipation.
- Monitor the operating temperature to ensure it stays within the range of -40°C to 125°C.
Storage and Handling:
- Store the device in a dry environment with temperatures between -65°C and 150°C.
- Handle the device with care to avoid static damage.
By following these instructions, you can effectively configure and operate the MP3394S 4-Phase Buck Controller.
(For reference only)View more about MP3394S on main site