ACPL-W61LV

ACPL-W61LV


Specifications
SKU
12606262
Details

BUY ACPL-W61LV https://www.utsource.net/itm/p/12606262.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 3.0 5.0 5.5 V Supply voltage for the input side
Output Voltage VOUT 2.7 5.0 5.5 V Supply voltage for the output side
Isolation Voltage VIORM - - 5000 Vpk Maximum repetitive peak isolation voltage
Working Isolation Voltage VIOWM - - 1200 Vrms Maximum working isolation voltage
Input Current IIN 1.0 1.5 2.0 mA Typical input current at nominal conditions
Output Current IOUT 1.0 1.5 2.0 mA Typical output current at nominal conditions
Propagation Delay Time tPLH 1.0 1.5 2.5 渭s Propagation delay time from input to output (low to high)
Propagation Delay Time tPHL 1.0 1.5 2.5 渭s Propagation delay time from input to output (high to low)
Rise Time tr 0.1 0.2 0.3 渭s Rise time of output signal
Fall Time tf 0.1 0.2 0.3 渭s Fall time of output signal
Common Mode Transient Immunity (CMTI) CMTI - - 25 kV/渭s Common mode transient immunity
Operating Temperature Toper -40 - 125 掳C Operating temperature range
Storage Temperature Tstg -65 - 150 掳C Storage temperature range

Instructions for Use:

  1. Power Supply:

    • Ensure the input voltage (VIN) is within the specified range (3.0V to 5.5V).
    • Ensure the output voltage (VOUT) is within the specified range (2.7V to 5.5V).
  2. Isolation:

    • Do not exceed the maximum isolation voltage (VIORM) of 5000 Vpk.
    • Ensure the working isolation voltage (VIOWM) does not exceed 1200 Vrms.
  3. Current Ratings:

    • The input current (IIN) should be between 1.0 mA and 2.0 mA.
    • The output current (IOUT) should be between 1.0 mA and 2.0 mA.
  4. Timing Parameters:

    • The propagation delay times (tPLH and tPHL) should be considered for timing-sensitive applications.
    • The rise time (tr) and fall time (tf) should be within the specified ranges to ensure proper signal integrity.
  5. Environmental Conditions:

    • Operate the device within the operating temperature range (-40掳C to 125掳C).
    • Store the device within the storage temperature range (-65掳C to 150掳C).
  6. Common Mode Transient Immunity (CMTI):

    • The device can handle common mode transients up to 25 kV/渭s, which is important for high-noise environments.
  7. Handling and Storage:

    • Handle the device with care to avoid damage to the isolation barrier.
    • Store the device in a dry and cool environment to prevent degradation.
  8. Mounting:

    • Follow the recommended PCB layout guidelines to ensure optimal performance and reliability.
    • Ensure proper grounding and shielding to minimize electromagnetic interference (EMI).
(For reference only)

View more about ACPL-W61LV on main site