Details
BUY ACPL-W61LV https://www.utsource.net/itm/p/12606262.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 3.0 | 5.0 | 5.5 | V | Supply voltage for the input side |
| Output Voltage | VOUT | 2.7 | 5.0 | 5.5 | V | Supply voltage for the output side |
| Isolation Voltage | VIORM | - | - | 5000 | Vpk | Maximum repetitive peak isolation voltage |
| Working Isolation Voltage | VIOWM | - | - | 1200 | Vrms | Maximum working isolation voltage |
| Input Current | IIN | 1.0 | 1.5 | 2.0 | mA | Typical input current at nominal conditions |
| Output Current | IOUT | 1.0 | 1.5 | 2.0 | mA | Typical output current at nominal conditions |
| Propagation Delay Time | tPLH | 1.0 | 1.5 | 2.5 | 渭s | Propagation delay time from input to output (low to high) |
| Propagation Delay Time | tPHL | 1.0 | 1.5 | 2.5 | 渭s | Propagation delay time from input to output (high to low) |
| Rise Time | tr | 0.1 | 0.2 | 0.3 | 渭s | Rise time of output signal |
| Fall Time | tf | 0.1 | 0.2 | 0.3 | 渭s | Fall time of output signal |
| Common Mode Transient Immunity (CMTI) | CMTI | - | - | 25 | kV/渭s | Common mode transient immunity |
| Operating Temperature | Toper | -40 | - | 125 | 掳C | Operating temperature range |
| Storage Temperature | Tstg | -65 | - | 150 | 掳C | Storage temperature range |
Instructions for Use:
Power Supply:
- Ensure the input voltage (VIN) is within the specified range (3.0V to 5.5V).
- Ensure the output voltage (VOUT) is within the specified range (2.7V to 5.5V).
Isolation:
- Do not exceed the maximum isolation voltage (VIORM) of 5000 Vpk.
- Ensure the working isolation voltage (VIOWM) does not exceed 1200 Vrms.
Current Ratings:
- The input current (IIN) should be between 1.0 mA and 2.0 mA.
- The output current (IOUT) should be between 1.0 mA and 2.0 mA.
Timing Parameters:
- The propagation delay times (tPLH and tPHL) should be considered for timing-sensitive applications.
- The rise time (tr) and fall time (tf) should be within the specified ranges to ensure proper signal integrity.
Environmental Conditions:
- Operate the device within the operating temperature range (-40掳C to 125掳C).
- Store the device within the storage temperature range (-65掳C to 150掳C).
Common Mode Transient Immunity (CMTI):
- The device can handle common mode transients up to 25 kV/渭s, which is important for high-noise environments.
Handling and Storage:
- Handle the device with care to avoid damage to the isolation barrier.
- Store the device in a dry and cool environment to prevent degradation.
Mounting:
- Follow the recommended PCB layout guidelines to ensure optimal performance and reliability.
- Ensure proper grounding and shielding to minimize electromagnetic interference (EMI).
View more about ACPL-W61LV on main site