TQ2-12V

TQ2-12V


Specifications
SKU
12606317
Details

BUY TQ2-12V https://www.utsource.net/itm/p/12606317.html

Parameter Description Value
Model Model Number TQ2-12V
Type Relay Type SPDT (Single Pole Double Throw)
Voltage Coil Voltage 12V DC
Current Coil Current 40mA
Power Coil Power Consumption 0.48W
Contact Form Contact Configuration 1C/O + 1C/C
Contact Rating Contact Load (Resistive) 10A at 250V AC
Insulation Resistance Between Contacts and Coil >100M惟 at 500V DC
Dielectric Strength Between Contacts and Coil 1500V AC for 1 minute
Operating Temperature Operating Temperature Range -40掳C to +85掳C
Storage Temperature Storage Temperature Range -40掳C to +125掳C
Mechanical Life Mechanical Operations 10 million cycles
Electrical Life Electrical Operations (at rated load) 100,000 cycles
Weight Weight 10g

Instructions for Use:

  1. Installation:

    • Ensure the relay is mounted on a flat, stable surface.
    • Use the provided mounting holes or clips for secure installation.
  2. Wiring:

    • Connect the coil terminals to a 12V DC power supply.
    • Connect the common (COM) terminal to the circuit you wish to control.
    • Connect the normally open (NO) and normally closed (NC) terminals to the respective parts of your circuit.
  3. Operation:

    • When the coil is energized (12V DC applied), the relay will switch from the NC to the NO contact.
    • When the coil is de-energized, the relay will return to its default state (NC contact).
  4. Safety Precautions:

    • Do not exceed the rated voltage and current for the coil and contacts.
    • Ensure proper insulation and isolation to prevent electrical shock.
    • Avoid operating the relay in environments with high humidity, corrosive gases, or excessive dust.
  5. Maintenance:

    • Regularly inspect the relay for signs of wear or damage.
    • Clean the relay using a soft, dry cloth. Avoid using abrasive materials or solvents.
  6. Troubleshooting:

    • If the relay fails to operate, check the power supply and connections.
    • If the relay operates intermittently, check for loose connections or damaged components.
    • If the relay is noisy, ensure it is securely mounted and free from external vibrations.
(For reference only)

View more about TQ2-12V on main site