Details
BUY A3120 DIP8 https://www.utsource.net/itm/p/12606328.html
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage | Vcc | 4.5 | - | 5.5 | V |
| Operating Current | Icc | 5 | 10 | 15 | mA |
| Output Current | Iout | 0.5 | 1.0 | 1.5 | mA |
| Sensitivity | S | 100 | 200 | 300 | Gauss |
| Hysteresis | Hys | 20 | 50 | 80 | Gauss |
| Response Time | Tr | 1 | 2 | 3 | 渭s |
| Output Low Voltage | Vol | 0.2 | 0.4 | 0.6 | V |
| Output High Voltage | Voh | 4.0 | 4.5 | 5.0 | V |
| Operating Temperature | Topr | -40 | - | 85 | 掳C |
| Storage Temperature | Tstg | -55 | - | 125 | 掳C |
Instructions for A3120 DIP8
Power Supply:
- Connect the Vcc pin to a stable power supply between 4.5V and 5.5V.
- Connect the GND pin to the ground of the power supply.
Output Configuration:
- The output pin (OUT) is open-collector, which means it can sink current but not source it. Use an external pull-up resistor to Vcc to ensure a high state when the sensor is not active.
- The recommended value for the pull-up resistor is typically between 1k惟 and 10k惟.
Magnetic Field Sensing:
- Place the sensor in the magnetic field you wish to detect. The sensitivity of the A3120 is between 100 and 300 Gauss.
- The hysteresis ensures that the output does not oscillate rapidly due to small fluctuations in the magnetic field.
Response Time:
- The typical response time of the A3120 is 2 渭s, allowing it to react quickly to changes in the magnetic field.
Temperature Considerations:
- Ensure that the operating temperature remains within the range of -40掳C to 85掳C for reliable operation.
- Store the device in temperatures between -55掳C and 125掳C.
Handling Precautions:
- Handle the A3120 with care to avoid damage from static electricity.
- Avoid exposing the device to excessive mechanical stress or moisture.
Testing and Troubleshooting:
- Verify the power supply connections and ensure the correct polarity.
- Check the pull-up resistor connection to the output pin.
- Test the sensor in a known magnetic field to confirm proper operation.
View more about A3120 DIP8 on main site