Details
BUY 832AWP-1A-C 24VDC https://www.utsource.net/itm/p/12606368.html
| Parameter | Description |
|---|---|
| Model Number | 832AWP-1A-C 24VDC |
| Type | Solenoid Valve |
| Voltage | 24V DC |
| Current | 0.35A (nominal) |
| Power Consumption | 8.4W (nominal) |
| Coil Resistance | 68惟 (nominal) |
| Valve Type | Normally Closed (NC) |
| Flow Rate | 150 L/min (water at 20掳C) |
| Max. Pressure | 10 bar |
| Operating Temperature | -10掳C to +60掳C |
| Connection Type | G1/4" (threaded) |
| Material | Brass body, stainless steel plunger, NBR seals |
| Weight | 250g |
| IP Rating | IP65 (dust tight, protected against water jets from any direction) |
Instructions
Installation:
- Ensure the valve is installed in a location that is dry and free from excessive vibration.
- Connect the valve to the power supply using the appropriate wiring. The positive terminal should be connected to the red wire, and the negative terminal to the black wire.
- Install the valve in the pipeline with the flow direction indicated on the valve body.
Operation:
- When the valve is energized, it will open, allowing fluid to flow through the valve.
- When the power is disconnected, the valve will return to its normally closed position, stopping the flow of fluid.
Maintenance:
- Regularly inspect the valve for signs of wear or damage.
- Clean the valve and its components as needed to prevent blockages.
- Replace seals if they show signs of degradation.
Safety:
- Do not exceed the maximum operating pressure or temperature.
- Ensure the valve is properly grounded to avoid electrical hazards.
- Always turn off the power supply before performing any maintenance or installation tasks.
Troubleshooting:
- Valve does not open: Check the power supply and wiring connections. Ensure the coil is not damaged.
- Leakage: Inspect the seals and replace if necessary. Check the valve body for any damage.
- Excessive noise: Ensure the valve is properly installed and not subjected to excessive pressure or flow rates.