Details
BUY YSH-13 https://www.utsource.net/itm/p/12606410.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Unique identifier for the component | YSH-13 |
| Type | Type of component | Sensor |
| Function | Primary function of the component | Temperature Sensor |
| Operating Voltage | Voltage range for operation | 3.3V to 5V |
| Current Consumption | Current drawn during operation | 0.5mA |
| Temperature Range | Range of temperatures it can measure | -40掳C to 125掳C |
| Accuracy | Precision of temperature measurement | 卤0.5掳C |
| Response Time | Time taken to respond to temperature changes | 500ms |
| Output Signal | Type of output signal | Analog (0-5V) |
| Package Type | Physical package type | TO-92 |
| Pin Configuration | Pin layout | 3-Pin (GND, VCC, OUT) |
| Operating Humidity | Humidity range for operation | 0% to 95% RH |
| Storage Temperature | Temperature range for storage | -65掳C to 150掳C |
Instructions for Use
Power Supply:
- Connect the VCC pin to a power supply within the operating voltage range (3.3V to 5V).
- Connect the GND pin to the ground of the power supply.
Signal Output:
- The OUT pin provides an analog output signal that varies linearly with temperature.
- The output voltage ranges from 0V to 5V, corresponding to the temperature range of -40掳C to 125掳C.
Calibration:
- For accurate temperature readings, calibrate the sensor using a known temperature reference.
- Use the following formula to convert the output voltage to temperature: [ text{Temperature (掳C)} = left( frac{text{Output Voltage (V)}}{5V} right) times 165掳C - 40掳C ]
Mounting:
- Ensure the sensor is mounted in a location where it can accurately measure the desired temperature.
- Avoid placing the sensor near heat sources or in direct sunlight to prevent inaccurate readings.
Handling:
- Handle the sensor with care to avoid damage to the pins or the internal components.
- Do not exceed the maximum operating temperature or humidity levels to ensure long-term reliability.
Testing:
- Before deploying the sensor in a critical application, test it under various conditions to ensure it meets the required performance standards.
Storage:
- Store the sensor in a dry environment within the specified storage temperature range to prevent degradation.
View more about YSH-13 on main site