Details
BUY BYP302 https://www.utsource.net/itm/p/12606411.html
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Forward Voltage | V_F | - | 1.2 | 1.8 | V |
| Reverse Breakdown Voltage | V_BR | 300 | - | - | V |
| Maximum Forward Current | I_F | - | - | 50 | mA |
| Reverse Leakage Current | I_R | - | - | 5 | 渭A |
| Operating Temperature | T_op | -40 | - | 85 | 掳C |
| Storage Temperature | T_stg | -65 | - | 150 | 掳C |
Instructions for Use:
- Forward Voltage (V_F): Ensure that the forward voltage across the diode does not exceed 1.8V to avoid damage.
- Reverse Breakdown Voltage (V_BR): The diode is designed to withstand up to 300V in reverse bias. Do not exceed this voltage to prevent breakdown.
- Maximum Forward Current (I_F): The maximum continuous forward current should not exceed 50mA to avoid overheating and potential failure.
- Reverse Leakage Current (I_R): Under normal operating conditions, the reverse leakage current should be less than 5渭A. Higher leakage currents may indicate a faulty diode.
- Operating Temperature (T_op): The diode can operate within the temperature range of -40掳C to 85掳C. Operating outside this range can affect performance and reliability.
- Storage Temperature (T_stg): When storing the diode, ensure the temperature remains between -65掳C and 150掳C to maintain its integrity.
Handling and Storage:
- Static Sensitivity: Handle the diode with care to avoid static discharge, which can damage the component.
- Moisture Sensitivity: Store the diode in a dry environment to prevent moisture damage.
- Physical Handling: Avoid applying excessive force or bending the leads, as this can cause mechanical stress and potential failure.
View more about BYP302 on main site