| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 4.5 | 5 | 5.5 | V | Operating supply voltage |
| Output Current | Iout | - | 500 | 700 | mA | Maximum output current |
| Quiescent Current | Iq | - | 3 | 5 | mA | Quiescent current at no load |
| Dropout Voltage | Vdo | - | 200 | 300 | mV | Voltage difference between input and output when fully loaded |
| Efficiency | 畏 | 80 | 90 | 95 | % | Efficiency at full load |
| Operating Temperature | Topr | -40 | 25 | 85 | 掳C | Operating temperature range |
| Storage Temperature | Tstg | -65 | - | 150 | 掳C | Storage temperature range |
| Junction Temperature | Tj | - | - | 150 | 掳C | Maximum junction temperature |
| Thermal Resistance | Rth | - | 40 | 50 | 掳C/W | Thermal resistance (junction to ambient) |
Instructions for Using FA5515N
Power Supply:
- Ensure the supply voltage is within the specified range of 4.5V to 5.5V.
- Use appropriate decoupling capacitors (typically 10渭F and 0.1渭F) close to the input and output pins to stabilize the power supply.
Output Load:
- The maximum output current should not exceed 700mA.
- For optimal performance, keep the load current within the typical range of 500mA.
Thermal Management:
- Ensure adequate heat dissipation to keep the junction temperature below 150掳C.
- Use a heatsink if the device is operating near its maximum current or in high ambient temperatures.
Operating Conditions:
- The device is designed to operate within the temperature range of -40掳C to 85掳C.
- Store the device in a temperature range of -65掳C to 150掳C.
Efficiency:
- The efficiency is maximized at full load conditions.
- Monitor the efficiency to ensure it remains within the 80% to 95% range for optimal performance.
Dropout Voltage:
- The dropout voltage is typically 200mV to 300mV.
- Ensure the input voltage is at least 300mV higher than the output voltage to maintain regulation.
Quiescent Current:
- The quiescent current is typically 3mA and can go up to 5mA.
- This current is drawn even when there is no load on the output.
Mounting and Handling:
- Follow standard ESD (Electrostatic Discharge) precautions during handling and mounting.
- Ensure proper soldering techniques to avoid thermal damage.
By following these guidelines, you can ensure reliable and efficient operation of the FA5515N.
(For reference only)View more about FA5515N on main site