| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 28 | V | Operating input voltage range |
| Output Voltage | VOUT | - | 3.3 | - | V | Nominal output voltage |
| Output Current | IOUT | - | - | 3 | A | Maximum continuous output current |
| Efficiency | 畏 | - | 90 | - | % | Typical efficiency at full load |
| Switching Frequency | fSW | - | 600 | - | kHz | Typical switching frequency |
| Quiescent Current | IQ | - | 10 | - | 渭A | Quiescent current at no load |
| Dropout Voltage | VDO | - | 1.2 | - | V | Typical dropout voltage |
| Thermal Shutdown | TSD | - | 160 | - | 掳C | Temperature at which thermal shutdown occurs |
| Operating Temperature | TA | -40 | - | 125 | 掳C | Ambient operating temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C | Storage temperature range |
Instructions for Use
Input Voltage (VIN):
- Ensure the input voltage is within the specified range of 4.5V to 28V.
- Avoid exceeding the maximum input voltage to prevent damage to the device.
Output Voltage (VOUT):
- The nominal output voltage is 3.3V. If a different output voltage is required, adjust the external feedback resistor network accordingly.
Output Current (IOUT):
- The device can provide up to 3A of continuous output current. For higher currents, consider using additional heat sinking or a more powerful device.
Efficiency (畏):
- The typical efficiency is 90% at full load. Monitor the efficiency under actual operating conditions to ensure optimal performance.
Switching Frequency (fSW):
- The typical switching frequency is 600kHz. This can be adjusted by modifying the external components if necessary.
Quiescent Current (IQ):
- The quiescent current is typically 10渭A. This low current draw helps minimize power consumption when the device is not actively supplying load current.
Dropout Voltage (VDO):
- The typical dropout voltage is 1.2V. This is the minimum difference between the input and output voltages required for the regulator to maintain regulation.
Thermal Shutdown (TSD):
- The device will shut down if the internal temperature exceeds 160掳C to prevent thermal damage. Ensure adequate cooling, especially under high load conditions.
Operating Temperature (TA):
- The device can operate in ambient temperatures ranging from -40掳C to 125掳C. Ensure that the device is not exposed to temperatures outside this range.
Storage Temperature (TSTG):
- Store the device in temperatures ranging from -65掳C to 150掳C to ensure long-term reliability.
Additional Notes:
- Always refer to the datasheet for detailed specifications and application notes.
- Proper PCB layout and component selection are crucial for optimal performance and reliability.
View more about IXRFD630 on main site