Details
BUY KIA578R050PI https://www.utsource.net/itm/p/12606491.html
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Input Voltage | VIN | 4.5 to 28 | V |
| Output Voltage | VOUT | 5.0 | V |
| Output Current | IOUT | 0.5 | A |
| Efficiency | η | Up to 92% | % |
| Operating Temperature | TOPR | -40 to 85 | °C |
| Storage Temperature | TSTG | -40 to 125 | °C |
| Quiescent Current | IQ | 2.5 | mA |
| Load Regulation | ΔVOUT | ±1 | % |
| Line Regulation | ΔVOUT | ±1 | % |
| Ripple and Noise | VRMS | <50 | mVp-p |
| Dropout Voltage | VDROPOUT | 1.2 | V |
| Protection Features | - | Overcurrent, Overtemperature, Short-Circuit | - |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) within the range of 4.5V to 28V to the input terminal.
- Ensure that the input power supply is stable and free from excessive ripple and noise.
Output Connection:
- Connect the load to the output terminal (VOUT).
- The output voltage is fixed at 5.0V and can provide up to 0.5A of current.
Thermal Management:
- Ensure adequate heat dissipation if operating at high temperatures or under heavy loads.
- Place the device on a heatsink or ensure good airflow around the component.
Protection:
- The device includes overcurrent, overtemperature, and short-circuit protection.
- In the event of a fault, the device will automatically shut down to prevent damage.
Storage and Handling:
- Store the device in a dry, cool place within the temperature range of -40°C to 125°C.
- Handle with care to avoid mechanical stress or damage to the leads.
Testing:
- Before connecting the device to a live circuit, verify the input voltage and ensure all connections are correct.
- Test the output voltage and current to confirm proper operation.
Compliance:
- Ensure that the device is used in compliance with all relevant safety and regulatory standards.
View more about KIA578R050PI on main site