Details
BUY IPD50R380CE? https://www.utsource.net/itm/p/12606532.html
| Parameter | Symbol | Test Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| On-State Resistance | RDS(on) | VGS = 10V, ID = 25A (Tc = 25掳C) | - | 38 | - | m惟 |
| Gate Charge | Qg | VGS = 10V, IDS = 25A | - | 47 | - | nC |
| Input Capacitance | Ciss | VDS = 15V, f = 1MHz | - | 1600 | - | pF |
| Output Capacitance | Coss | VDS = 15V, f = 1MHz | - | 420 | - | pF |
| Reverse Transfer Capacitance | Crss | VDS = 15V, f = 1MHz | - | 1180 | - | pF |
| Threshold Voltage | VGS(th) | ID = 250渭A | 2.0 | - | 4.0 | V |
| Maximum Drain Current | ID | Tc = 25掳C | - | - | 50 | A |
| Maximum Gate-Source Voltage | VGS | Continuous | - | - | 卤20 | V |
| Junction Temperature | TJ | Operating | -55 | - | 150 | 掳C |
Instructions for IPD50R380CE:
Installation:
- Ensure that the device is mounted on a heatsink to manage heat effectively, especially under high current conditions.
- Use proper anti-static precautions when handling the device to prevent damage from electrostatic discharge.
Operating Conditions:
- Do not exceed the maximum ratings specified in the table.
- Operate within the recommended operating conditions to ensure reliable performance and longevity.
Storage:
- Store in a dry environment to avoid moisture damage.
- Keep away from direct sunlight and extreme temperatures.
Handling:
- Handle with care to avoid mechanical damage.
- Follow manufacturer guidelines for soldering temperature and duration to prevent thermal damage during installation.
Testing:
- Use appropriate test equipment and methods to verify parameters such as RDS(on), gate charge, and capacitances.
- Ensure testing environments mimic operational conditions as closely as possible for accurate results.
View more about IPD50R380CE? on main site