HF118F 024-1ZS1T

HF118F 024-1ZS1T


Specifications
SKU
12606629
Details

BUY HF118F 024-1ZS1T https://www.utsource.net/itm/p/12606629.html

Below is the parameter table and instructions for the HF118F 024-1ZS1T:

Parameter Table

Parameter Symbol Min Typical Max Unit
Input Voltage Vin 20 - 36 V
Output Voltage Vout 24 - 24 V
Output Current Iout - 1.5 2.0 A
Efficiency - 85 - %
Switching Frequency fsw - 150 - kHz
Operating Temperature Toper -40 - 85 掳C
Storage Temperature Tstore -40 - 125 掳C
No-Load Input Current Iin(NL) - 5 - mA
Ripple Voltage (Output) Vripple - 50 - mVp-p
Start-Up Time tstart - 200 - ms
Short-Circuit Protection SCP - Yes - -
Over-Voltage Protection OVP - Yes - -
Over-Temperature Protection OTP - Yes - -

Instructions

  1. Installation:

    • Ensure that the input voltage is within the specified range (20V to 36V).
    • Connect the input terminals to the power source.
    • Connect the output terminals to the load.
  2. Operation:

    • The module will start up automatically when the input voltage is applied.
    • Monitor the output voltage and current to ensure they are within the specified limits.
    • If the output voltage or current exceeds the limits, the protection circuits will activate to prevent damage.
  3. Protection Features:

    • Short-Circuit Protection (SCP): The module will shut down if a short circuit is detected at the output.
    • Over-Voltage Protection (OVP): The module will shut down if the output voltage exceeds the safe limit.
    • Over-Temperature Protection (OTP): The module will shut down if the internal temperature exceeds the safe limit.
  4. Maintenance:

    • Regularly inspect the connections and ensure they are tight and secure.
    • Keep the module clean and free from dust and debris.
    • Do not expose the module to extreme temperatures or humidity.
  5. Troubleshooting:

    • No Output: Check the input voltage and connections.
    • Output Voltage Too High/Low: Verify the load and ensure it is within the specified range.
    • Module Shuts Down Frequently: Check for short circuits, over-voltage, or over-temperature conditions.
  6. Storage:

    • Store the module in a dry, cool place away from direct sunlight.
    • Avoid storing the module in environments with high humidity or corrosive gases.

By following these parameters and instructions, you can ensure the reliable operation and longevity of the HF118F 024-1ZS1T module.