Details
BUY FGH60N60SMD https://www.utsource.net/itm/p/12606632.html
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | 600 | - | V | Continuous |
| Gate-Source Voltage | VGS | -20 | - | 20 | V | Continuous |
| Drain Current | ID | - | 60 | - | A | @ TC = 25掳C |
| Continuous Drain Current | ID(DC) | - | 38 | - | A | @ TC = 100掳C |
| Pulse Drain Current | ID(m) | - | 120 | - | A | @ TC = 25掳C, tp = 10 渭s, IG = 10 A |
| Power Dissipation | PTOT | - | - | 140 | W | @ TC = 25掳C |
| Junction Temperature | TJ | - | - | 175 | 掳C | Maximum |
| Storage Temperature | TSTG | -55 | - | 150 | 掳C | |
| Thermal Resistance (Junction to Case) | Rth(j-c) | - | - | 0.4 | 掳C/W | |
| Input Capacitance | Ciss | - | 2900 | - | pF | @ VDS = 400 V, f = 1 MHz |
| Output Capacitance | Coss | - | 220 | - | pF | @ VDS = 400 V, f = 1 MHz |
| Reverse Transfer Capacitance | Crss | - | 360 | - | pF | @ VDS = 400 V, f = 1 MHz |
| Turn-On Delay Time | td(on) | - | 42 | - | ns | @ ID = 20 A, VGS = 15 V, RG = 2 惟 |
| Rise Time | tr | - | 40 | - | ns | @ ID = 20 A, VGS = 15 V, RG = 2 惟 |
| Turn-Off Delay Time | td(off) | - | 35 | - | ns | @ ID = 20 A, VGS = -15 V, RG = 2 惟 |
| Fall Time | tf | - | 45 | - | ns | @ ID = 20 A, VGS = -15 V, RG = 2 惟 |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to manage thermal resistance.
- Handle with care to avoid static damage.
Operating Conditions:
- Do not exceed the maximum ratings under any operating conditions.
- Ensure the junction temperature does not exceed 175掳C.
Gate Drive:
- Use appropriate gate resistors to control switching times and minimize overshoot and ringing.
- Ensure the gate-source voltage is within the specified range to prevent damage.
Thermal Management:
- Use a heatsink or cooling solution to maintain the device within its thermal limits.
- Monitor the case temperature to ensure it does not exceed the maximum allowable value.
Storage:
- Store in a dry, cool environment to prevent moisture damage.
- Follow ESD (Electrostatic Discharge) precautions during storage and handling.
Testing:
- Use recommended test conditions to accurately measure parameters.
- Ensure all test equipment is properly calibrated.
Application Notes:
- Refer to the datasheet and application notes for detailed information on specific applications and circuit design considerations.
View more about FGH60N60SMD on main site