| Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 1.7 | - | 3.6 | V |
| Supply Current | IDD | Quiescent (no load) | - | 0.5 | - | μA |
| Output Current | IOUT | Continuous | - | 200 | - | mA |
| Output Voltage | VOUT | No load | 1.2 | - | 3.3 | V |
| Dropout Voltage | VDROPOUT | IOUT = 100mA | - | 0.2 | - | V |
| Load Regulation | ΔVOUT/ΔILOAD | 1mA to 100mA | - | 0.1 | - | % |
| Line Regulation | ΔVOUT/ΔVIN | 1.7V to 3.6V | - | 0.05 | - | % |
| Thermal Shutdown | TSD | Activation | - | 150 | - | °C |
| Operating Temperature | TOPR | Range | -40 | - | 125 | °C |
| Storage Temperature | TSTG | Range | -65 | - | 150 | °C |
Instructions for Use
Supply Voltage (VDD):
- Ensure the supply voltage is within the range of 1.7V to 3.6V to avoid damage to the device.
Supply Current (IDD):
- The quiescent current is typically 0.5μA. This low current consumption makes it suitable for battery-powered applications.
Output Current (IOUT):
- The device can provide a continuous output current of up to 200mA. Ensure that the load does not exceed this limit to prevent overheating or damage.
Output Voltage (VOUT):
- The output voltage ranges from 1.2V to 3.3V, depending on the specific model. Verify the output voltage requirement of your application.
Dropout Voltage (VDROPOUT):
- The dropout voltage is typically 0.2V at an output current of 100mA. This ensures efficient operation even when the input voltage is close to the output voltage.
Load Regulation:
- The load regulation is 0.1% from 1mA to 100mA. This indicates the stability of the output voltage under varying load conditions.
Line Regulation:
- The line regulation is 0.05% over the input voltage range of 1.7V to 3.6V. This ensures minimal changes in output voltage due to variations in input voltage.
Thermal Shutdown (TSD):
- The device has thermal shutdown protection that activates at approximately 150°C. This prevents damage due to excessive heat.
Operating Temperature (TOPR):
- The operating temperature range is from -40°C to 125°C. Ensure the device operates within this range to maintain reliable performance.
Storage Temperature (TSTG):
- The storage temperature range is from -65°C to 150°C. Store the device in a suitable environment to avoid degradation.
Layout Considerations:
- Use short, wide traces for power and ground connections to minimize inductance and resistance.
- Place bypass capacitors close to the input and output pins to filter noise and ensure stable operation.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Follow proper soldering techniques to prevent thermal stress and ensure a secure connection.