BTA208X-800B

BTA208X-800B


Specifications
SKU
12606748
Details

BUY BTA208X-800B https://www.utsource.net/itm/p/12606748.html

Parameter Symbol Min Typical Max Unit
Rated RMS On-State Current IT(RMS) - 208 - A
Peak On-State Current ITSM - 350 - A
On-State Voltage Drop at 208A VT(208A) - 1.2 - V
Gate Trigger Current IG(T) 5 - 50 mA
Holding Current IH 5 - 50 mA
Maximum Off-State Voltage VDRM - - 800 V
Maximum Repetitive Peak Off-State Voltage VRRM - - 800 V
Junction Temperature Range TJ -40 - 125 掳C
Storage Temperature Range TSTG -40 - 150 掳C

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to manage junction temperature.
    • Handle with care to avoid damage to the leads and body.
  2. Circuit Design:

    • Ensure the circuit design accounts for the maximum ratings, especially the peak on-state current and off-state voltage.
    • Use appropriate gate resistors to control the gate trigger current.
  3. Thermal Management:

    • Maintain the junction temperature within the specified range to ensure reliable operation.
    • Use thermal paste between the device and heat sink for better thermal conductivity.
  4. Gate Drive:

    • Apply a sufficient gate trigger current (IG(T)) to ensure reliable turn-on.
    • Ensure the holding current (IH) is maintained to keep the device in the on-state.
  5. Storage and Operating Conditions:

    • Store the device in a dry, cool place to prevent moisture damage.
    • Operate within the specified storage temperature range to avoid thermal stress.
  6. Safety Precautions:

    • Use appropriate protective equipment when handling high-voltage circuits.
    • Follow all relevant safety standards and guidelines for high-power electronics.
(For reference only)

View more about BTA208X-800B on main site