Details
BUY D40E5 https://www.utsource.net/itm/p/12606763.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Device Identifier | D40E5 |
| Type | Silicon Controlled Rectifier (SCR) | - |
| Maximum RMS Voltage (VRRM) | Maximum repetitive peak reverse voltage that can be applied continuously | 400 V |
| Maximum RMS On-State Current (IT(RMS)) | Maximum RMS on-state current at 25掳C ambient temperature | 5 A |
| Peak Surge Current (ITSM) | Maximum non-repetitive surge current (8.3 ms sine wave, one cycle) | 100 A |
| Gate Trigger Current (IGT) | Minimum gate current required to turn on the SCR | 50 mA |
| Holding Current (IH) | Minimum anode current required to maintain conduction after triggering | 10 mA |
| Power Dissipation (PD) | Maximum power dissipation at 25掳C ambient temperature | 100 W |
| Operating Temperature (TJ) | Junction operating temperature range | -40掳C to 125掳C |
| Storage Temperature (TSTG) | Storage temperature range | -65掳C to 150掳C |
| Case Style | Physical package type | TO-220 |
Instructions for Use
Mounting:
- Ensure proper heat sinking to manage thermal dissipation, especially under high current conditions.
- Use a heatsink with a thermal resistance suitable for the application to keep the junction temperature within the specified range.
Wiring:
- Connect the anode (A) to the positive side of the circuit.
- Connect the cathode (K) to the negative side of the circuit.
- The gate (G) should be connected to the control circuit to trigger the SCR.
Triggering:
- Apply a pulse of gate current (IGT) to turn on the SCR.
- The SCR will remain on as long as the anode current (IA) is above the holding current (IH).
Surge Handling:
- Ensure that the peak surge current (ITSM) does not exceed the rated value to avoid damage.
- Use appropriate fuses or circuit breakers to protect against overcurrent conditions.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it stays within the operating range.
- If the device is expected to operate near the maximum power dissipation, consider forced air cooling or a larger heatsink.
Storage:
- Store the device in a dry environment within the specified storage temperature range (TSTG).
Safety:
- Handle the device with care to avoid mechanical stress.
- Follow standard safety procedures when working with high voltages and currents.
View more about D40E5 on main site