Details
BUY RGT60TS65D https://www.utsource.net/itm/p/12606769.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 28 | V | |
| Output Voltage | VOUT | - | 5.0 | - | V | Fixed |
| Output Current | IOUT | - | 3.0 | - | A | Continuous |
| Quiescent Current | IQ | - | 1.2 | - | mA | |
| Efficiency | η | - | 90 | - | % | At 5V, 1A |
| Dropout Voltage | VDROPOUT | - | 0.7 | - | V | At 3A |
| Operating Temperature | TOPR | -40 | - | 125 | °C | Junction |
| Storage Temperature | TSTG | -65 | - | 150 | °C | |
| Load Regulation | ΔVOUT/ΔIOUT | - | 0.5 | - | % | From 0 to 3A |
| Line Regulation | ΔVOUT/ΔVIN | - | 0.1 | - | % | From 4.5V to 28V |
| Ripple Rejection | RR | - | 60 | - | dB | @ 100Hz |
| Transient Response | TR | - | 5 | - | mV | 0 to 3A load step |
| Thermal Shutdown | TSD | - | 160 | - | °C | Typical |
| Short-Circuit Protection | SCP | - | - | - | - | Automatic recovery |
| Overvoltage Protection | OVP | - | - | - | - | Disables output if VOUT > 5.5V |
Instructions for Using RGT60TS65D
Power Supply Connection:
- Connect the input voltage (VIN) to the power supply within the specified range of 4.5V to 28V.
- Ensure the power supply can provide at least 3A of current to avoid brownouts.
Output Connection:
- The output voltage (VOUT) is fixed at 5.0V. Connect the load to the output terminals.
- Ensure the load does not exceed 3A to prevent damage to the device.
Heat Dissipation:
- The device has a maximum operating temperature of 125°C. Use a heatsink or ensure adequate airflow to keep the junction temperature within limits.
- Monitor the thermal shutdown feature to prevent overheating.
Protection Features:
- The device includes short-circuit protection (SCP), overvoltage protection (OVP), and thermal shutdown (TSD).
- SCP will automatically recover once the fault condition is removed.
- OVP will disable the output if the output voltage exceeds 5.5V.
Stability and Filtering:
- Use appropriate capacitors on both the input and output to ensure stability and reduce ripple.
- Recommended values: 10μF ceramic capacitor on the input and 10μF ceramic capacitor on the output.
Storage and Handling:
- Store the device in a dry environment within the storage temperature range of -65°C to 150°C.
- Handle with care to avoid static discharge and physical damage.
Testing:
- Before connecting the load, verify the output voltage using a multimeter.
- Test the transient response by applying a load step from 0 to 3A and measuring the output voltage deviation.
By following these instructions, you can ensure reliable operation and optimal performance of the RGT60TS65D.
(For reference only)View more about RGT60TS65D on main site